| Motore di ricerca datesheet componenti elettronici |
|
M66290AFP Scheda tecnica(PDF) 53 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M66290AFP Scheda tecnica(HTML) 53 Page - Renesas Technology Corp |
|
53 / 54 page ![]() USB DEVICE CONTROLLER M66290AGP/FP MITSUBISHI <DIGITAL ASSP> 52 Pause-IR Update-IR 1 1 0 0 1 0 1 1 0 1 1 0 1 0 0 0 0 A Y B A/B D Q T D Q T Shift-DR/IR Clock-DR/IR Update-DR/IR 0 0 1 0 1 1 1 1 0 1 0 0 0 Exit2-IR Exit1-IR Shift-IR Capture-IR Select-IR-Scan Exit2-IR Select-DR-Scan Capture-DR Shift-DR Exit1-DR Pause-DR Exit2-DR Update-DR Test-Logic-Reset Run-Test-/Idle 1 Data input From previous cell Input select Test reset Parallel output stage Data output To next cell Shift register stage note: 0,1 shows the status of TMS input signal Figure. Status shif t of TAP controller Abstract of JTAG operations There are f our basic access to command register and to data register. And the access is executed based on the status shif t of TAP controller. TAP controller is shif ted of its status by the TMS input and make a control signal which is needed to each state. Capture operation Result of the boundary scan test or the f ixed data which is def ined to each register, is sampled. For operation, load the input data into shif t register stage. Shif t operation Through the boundary scan path, access f rom external is done. M66290A set the data f rom external and at the same time, output the data which is sampled by capture operation. For register operation, right shif t is executed among shif t register stage of each bit. Figure. Basic construction of JTAG related register IR path sequence Update operation In shif t operation, driv e the data which is set by external. For register operation, transf er the v alue which is set to shif t register stage, to parallel output stage. JTAG interf ace shif ts the internal state according to TMS input, and do two kinds of operations as f ollows. Both are basically executed in turn of "Capture -> Shif t -> Update". Set the command code into command register and when path sequence comes, select the data register which is the object of the operation. DR path sequence To selected data register, ref er or set the data. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |