Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

AS8118 Scheda tecnica(PDF) 9 Page - ams AG

Il numero della parte AS8118
Spiegazioni elettronici  Single Phase Instantaneous Energy Metering IC with On-Chip Calibration, Stepper Motor Drive and LED Output
PDF  30 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Produttore elettronici  AMSCO [ams AG]
Homepage  http://www.ams.com
Logo AMSCO - ams AG

AS8118 Scheda tecnica(HTML) 9 Page - ams AG

Back Button AS8118 Datasheet HTML 5Page - ams AG AS8118 Datasheet HTML 6Page - ams AG AS8118 Datasheet HTML 7Page - ams AG AS8118 Datasheet HTML 8Page - ams AG AS8118 Datasheet HTML 9Page - ams AG AS8118 Datasheet HTML 10Page - ams AG AS8118 Datasheet HTML 11Page - ams AG AS8118 Datasheet HTML 12Page - ams AG AS8118 Datasheet HTML 13Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 30 page
background image
Data Sheet AS8118
Revision 1.8, 15-Feb-05
Page 9 of 30
Anti-Creep Threshold Setting
The anti-creep threshold is programmable to ensure that the set threshold lies between the anti-creep current, a current level
at which no pulses must be generated and the start current. The programmable threshold levels have been set to
accommodate the various specified base currents (IB) of the meter and if the meter is direct connection (shunt resistor) or
connection is through a current transformer. The formulae for calculating the appropriate thresholds are as follows:
Shunt:
5
1
5
1
1000
4
*
I
*
I
*
th
_
ac
Start
B
=
=
Current Transformer:
5
1
5
1
1000
2
*
I
*
I
*
th
_
ac
Start
B
=
=
Parameter: Acreep_sel
(All values are given in mA, unless otherwise specified)
Setting
Ithreshold
IB (A)
IMAX(A)
(IB*4)
IMAX(A)
(IB*6)
Ianticreep
Shunt
Istarting
Shunt
Ianticreep
CT
Istarting
CT
2.3
1.5
6
9
1.2
6
0.6
3
00
2.3
2.5
10
15
2
10
1
5
01
7.4
5
20
30
4
20
2
10
14.8
10
40
60
8
40
4
20
10
14.8
15
60
90
12
60
6
30
29.7
20
80
120
16
80
8
40
11
29.7
30
120
n/a
20
100
10
50
The default Anti-Creep threshold (ac_th) is set at 7.4mA, best suited to a 30A (IB*6) or 20A (IB*4) meter. The default Anti-
Creep is the programmed threshold setting, without any programming required to the AS8118.
Summary of Programmable Parameters
The AS8118 programming options, along with the default settings have been summarised in the table below:
I Gain
CAL
MON/MOP
LED
Anti-Creep Threshold
20
8
100
100
2.32mA
16
16
200
200
7.43mA
432
400
400
14.90mA
64
800
800
29.70mA
1600
3200
6400
Note: The default settings have been highlighted.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com