9 / 13 page ![]() On/Off Control and Undervoltage Lockout SEL sets the active polarity of the logic inputs of the MAX1940. Connect ON_ to the same voltage as SEL to enable the respective OUT_ switch. Connect ON_ to the opposite voltage as SEL to disable the respective output (see Table 1). The output of a disabled switch enters a high-impedance state. The MAX1940 includes a UVLO circuit to prevent erro- neous switch operation when the input voltage goes low during startup and brownout conditions. Input voltages of less than 3.4V inhibit operation of the device. FAULT_ asserts low during an undervoltage lockout condition. Output Fault Protection and Autoreset The MAX1940 senses the switch output voltage and selects continuous current limiting for VOUT_ greater than 1V, or short-circuit current limiting for VOUT_ less than 1V. When VOUT_ is greater than 1V, the device operates in a continuous current-limit mode that limits output current to 0.9A. When VOUT_ is less than 1V, the device operates in short-circuit current-limit mode, sourcing 1.2A pulses to the load. When either fault con- dition persists for 20ms, the output turns off and its fault flag is asserted. The output automatically restarts 20ms after the short or overload is removed. The MAX1940 detects short-circuit removal by sourcing 25mA from the output and monitoring the output volt- age. When the voltage at the output exceeds 0.5V for 20ms, the fault flag resets, the output turns back on, and the 25mA current source turns off. Active loads are not expected to have measurable current when sup- plied with less than 0.5V. Thermal Shutdown Independent thermal shutdown for each channel per- mits normal operation of two switches to continue while a third experiences a thermal fault. The switch turns off and the FAULT_ output asserts low immediately when the junction temperature exceeds +160°C. Thermal shutdown does not utilize the 20ms fault-blanking time- out period. The switch turns on again and FAULT_ returns high when the junction temperature cools by +15°C. The switch cycles on and off if the overload condition persists, resulting in a pulsed output that reduces system power. Fault Indicators The MAX1940 provides an independent open-drain fault output (FAULT_) for each switch. Connect FAULT_ to IN_ through a 100k Ω pullup resistor for most applications. FAULT_ asserts low when any of the following conditions occur: • The input voltage is below the UVLO threshold. • The switch junction temperature exceeds the +160°C thermal-shutdown temperature limit. • The switch is in current-limit or short-circuit current- limit mode after the fault-blanking period (20ms) expires. The FAULT_ output deasserts after a 20ms delay once the fault condition is removed. Ensure that the MAX1940 input bypass capacitance prevents glitches from trigger- ing the FAULT_ outputs. Limit the input voltage slew rate to 0.2V/µs to prevent erroneous FAULT_ indications. To differentiate large capacitive loads from short cir- cuits or sustained overloads, the MAX1940 has an independent fault-blanking circuit for each switch. When a load transient causes the device to enter cur- rent limit, an internal counter monitors the duration of the fault. For load faults exceeding the 20ms fault- blanking time, the switch turns off, FAULT_ asserts low, and the device enters autoreset mode (see the Output Fault Protection and Autoreset Mode section). Only cur- rent-limit and short-circuit faults are blanked. Thermal overload faults and input voltage drops below the UVLO threshold immediately turn the switch off and assert FAULT_ low. Fault blanking allows the MAX1940 to handle USB loads that might not be fully compliant with USB specifi- cations. The MAX1940 successfully powers USB loads with additional bypass capacitance and/or large start- up currents while protecting the upstream power source. No fault is reported if the switch brings up the load within the 20ms blanking period. See Table 2 for a summary of current-limit and fault behavior. Triple USB Switch with Autoreset and Fault Blanking _______________________________________________________________________________________ 9 SEL ON_ OUT_ BEHAVIOR GND ON GND VIN OFF GND OFF VIN VIN ON Table 1. On/Off Control |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |