MPB80 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full rated load, 230 VAC. Varies with distribution of loads among outputs.
73
%
Minimum Loads
Single Output Models
0.0
Minimum load required on V1 for regulation of V2, V3.
MPB80-2000
1.5
Amps
All other Multiple Output Models
0.7
Ripple and Noise
Full load, 20 MHz bandwidth
See Model Selection Chart
Output Power
Convection cooled, continuous output power.
MPB80-10XX
72
MPB80-2000
61
MPB80-3000
63
Watts
MPB80-3300
43
Forced air cooled, 300 LFM, or convection cooled, peak
MPB80-10XX
100
output power 10% duty cycle, 30 seconds maximum.
MPB80-2000
80
MPB80-3000
80
Watts
MPB80-3300
61
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
2
%
Regulation
Varies by output. Total regulation includes: line changes from 85-132 VAC or
See Model Selection Chart
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
500
µS
5% max. deviation.
Turn-On Delay
Time required for initial output voltage stabilization.
2
Sec
Turn-On Rise Time
Time required for output voltage to rise from 10% to 90%.
20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
+3.3V
3.9
4.7
V
+5V, V1 & V2
5.8
6.8
12V
17.3
20.2
24V
32.2
37.8
48V
55.2
64.8
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Autoranging AC input automatically adjusts, no manual strapping required.
85
264
VAC
Input Frequency
AC input.
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated loads.
85
VAC
Hold-Up Time
After last AC line peak.
Full load @ 120 VAC
16
mS
Full load @ 220 VAC
20
Input Current
Single Output Models, 120 VAC
1.5
ARMS
Single Output Models, 230 VAC
0.75
Dual and Triple Output Models, 120 VAC
1.1
Dual and Triple Output Models, 230 VAC
0.55
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 230 VAC (one cycle).
32
APK
Operating Frequency
Switching frequency of main transformer.
60
68
kHz



Html Pages

1 2 3 4


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com