3 / 8 page ![]() INSTALLATION cont. WIRING cont. Terminal connections shown in Figure 4 are for a standard SPDT switch. Actuating the switch closes one circuit and simultaneously opens the second circuit. In this diagram, circuit between contacts 4 and 5 is made and circuit between contact 5 and 6 is broken at low liquid level. At high level, circuit between contacts 4 and 5 is broken and circuit between contact 5 and 6 is made. DIFFERENTIAL ADJUSTMENT The amount of level travel between “switch on” and “switch off” can be reduced from the maximum factory setting by raising the lower set of jam nuts. Minimum free play (differ- ential) of magnetic sleeve is 1⁄32". 1. Disconnect wiring from supply side of switch mecha- nism and electrical conduit or operating medium line connections to switch housing. 2. Perform system shut-down as required to relieve pres- sure from tank or vessel and drain off liquid “head” above control mounting position. Allow unit to cool. 3. Remove switch housing assembly by loosening enclos- ing tube nut located immediately below housing base. Refer to Figure 8 on page 7. 4. With switch housing removed, jam nuts and magnetic sleeve are now accessible, as shown in Figure 6. Raising the lower jam nuts will reduce the differential. As the first step in any adjustment procedure, the position of the upper and lower jam nuts should be established. NEVER CHANGE SETTING OF UPPER JAM NUTS AS THEY SUPPORT FLOAT ASSEMBLY SO THAT IT CAN- NOT TOUCH BOTTOM OF CHAMBER. 5. Loosen and remove upper jam nuts, guide washer, and magnetic sleeve. Lower jam nuts may now be adjusted to reduce the differential. NOTE: Be certain to tighten jam nuts securely after adjustment. 6. Replace magnetic sleeve on stem and position upper jam nuts to their original setting. Lock upper jam nuts to guide washer. 7. Reassemble control in reverse of steps 1 through 3, previ- ously described. 8. Test switch actuation by varying liquid level in tank or vessel. Figure 4 Figure 5 Figure 6 CAUTION: Before attempting any work on the control, be certain to pull disconnect switch or otherwise assure that electrical circuit(s) through control is deactivated. Close operating medium supply valve on controls equip- ment with pneumatic switch mechanisms. Receiver From Condenser To Evaporator INSTALLATION SHOWING LEVEL CONTROL (OR ALARM) ON A RECEIVER Desired Actuating Level Insulation End View Side View Chamber mark indicates actuating level DO NOT Insulate Switch Housing Mount control so mark on chamber corresponds to level desired in vessel. When control is used on a low temperature liquid, chamber and connection lines should be insulated as shown to prevent “boiling” in the float chamber and false level indications 4 RED Assembly B Load Load Line Ground GREEN Internal Circuit Close on Falling Level Close on Rising Level Common 5 YELLOW 6 BLUE Jam nuts. Slight play (gap) must be allowed (.03" [.8 mm] typical) Differential gap Magnetic sleeve 3 |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |