Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

IC227 Scheda tecnica(PDF) 3 Page - IC-Haus GmbH

Il numero della parte IC227
Spiegazioni elettronici  DUAL 11 GHz SAMPLING OSCILLOSCOPE
PDF  22 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Produttore elettronici  ICHAUS [IC-Haus GmbH]
Homepage  http://www.ichaus.biz
Logo ICHAUS - IC-Haus GmbH

IC227 Scheda tecnica(HTML) 3 Page - IC-Haus GmbH

  IC227 Datasheet HTML 1Page - IC-Haus GmbH IC227 Datasheet HTML 2Page - IC-Haus GmbH IC227 Datasheet HTML 3Page - IC-Haus GmbH IC227 Datasheet HTML 4Page - IC-Haus GmbH IC227 Datasheet HTML 5Page - IC-Haus GmbH IC227 Datasheet HTML 6Page - IC-Haus GmbH IC227 Datasheet HTML 7Page - IC-Haus GmbH IC227 Datasheet HTML 8Page - IC-Haus GmbH IC227 Datasheet HTML 9Page - IC-Haus GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 22 page
background image
preliminary
preliminary
iC227
DUAL 11 GHz SAMPLING OSCILLOSCOPE
Rev B1, Page 3/22
BLOCK DIAGRAM AND THEORY OF OPERATION
iC227 is a simple yet very fast and accurate oscillo-
scope, consisting of a micro-controller and high speed
ECL differential circuitry.
The micro-controller receives commands and re-
sponds via an isolated USB interface running in full
speed mode at 12 Mbit/s.
The sequential scope works by inserting incremental
delays between trigger and sample circuit.
ADC conversion can not start without a trigger event.
Once the trigger has been fired, a high-speed flip flop
is set and the programmable delay lines starts count-
ing time in 10 ps increments.
A fine tuning voltage adjusts final time delay with
one picoseconds resolution using DAC calibration data
from micro-controller flash memory.
A Sample is taken on both channels simultaneously
after delay line counting is completed.
It is important to note, that each ADC conversion re-
quires multiple trigger events, limiting the scope usage
to repetitive signals only.
Achieving highly accurate and repeatable time base is
done using proprietary self calibration and fine tuning
techniques.
The device time base is calibrated after assembly and
users have the option to run auto time base calibration.
Time base calibration takes long time, since time base
is scanned with 1 ps intervals and multiple cycles are
repeated, compared to time generated by the crystal
and stored in a flash calibration look up table.
There is no need for frequent time base calibration
since the ECL logic is stable over temperature.
Figure 1: Block Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com