11 / 25 page ![]() AN3407 Input current harmonics measurement Doc ID 018857 Rev 1 11/25 4 Input current harmonics measurement The internal THD optimizer increases the performance when the mains voltage reaches zero which reduces crossover distortion and avoids introducing offset. One of the main purposes of a PFC pre-conditioner is the correction of input current distortion, decreasing the harmonic contents below the limits of the relevant regulations. The board has been tested according to the European norm EN61000-3-2 Class-D, at full load and nominal input voltage mains. Figure 10 and 11 show the measurement results. Figure 10. EN61000-3-2 Class-D standard - 185 VAC/50 Hz, THD=4.86%, PF=0.993 at full load Figure 11. EN61000-3-2 Class-D standard - 230 VAC/50 Hz, THD=5.98%, PF=0.980 at full load |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|