Back Button AN4158 Datasheet HTML 10Page - STMicroelectronics AN4158 Datasheet HTML 11Page - STMicroelectronics AN4158 Datasheet HTML 12Page - STMicroelectronics AN4158 Datasheet HTML 13Page - STMicroelectronics AN4158 Datasheet HTML 14Page - STMicroelectronics AN4158 Datasheet HTML 15Page - STMicroelectronics AN4158 Datasheet HTML 16Page - STMicroelectronics AN4158 Datasheet HTML 17Page - STMicroelectronics AN4158 Datasheet HTML 18Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 34 page
background image
Peak current control with PWM and constant off-time
AN4158
14/34
DocID023635 Rev 2
3
Peak current control with PWM and constant off-time
The peak current control with PWM and constant off-time is one of the most common
algorithms implemented by stepper motor controllers.
The phase current is measured through a shunt resistor and the resulting voltage (see
Equation 4 A) is sent to a comparator input. The other input is a reference voltage setting
the peak current forced into the motor phase (Equation 4 B).
Equation 4
At the beginning of driving, the motor phase currents are zero and the controller turns on
one of the diagonals of the power bridge according to the expected current direction. The
phase current is increased until the target reference voltage is reached, then the controller
switches off the forcing side of the bridge making the phase current recirculate in the bottom
side of the power stage. The same effect may be obtained recirculating the current on the
top side; in this case the forcing side of the bridge is kept on and the opposite side is turned
on.
Figure 8. Constant off-time control sequence (low-side recirculation)
A
VSense IPh RSHUNT
=
B
VRef IPeak RSHUNT
=
V
Ref
I
Peak
V
BUS
V
Sense
I
Ph
R
SHUNT
R
SHUNT
V
BUS
V
Sense
I
Ph
R
SHUNT
V
BUS
VSense
I
Ph
t
OFF
AM15110v1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com