15 / 20 page ![]() clock cycle (Figure 10). After the not acknowledge, the MAX1069 is in HS-mode. The master must then send a repeated START followed by a slave address to initiate HS-mode communication. If the master generates a STOP condition, the MAX1069 returns to F/S-mode. Data Byte (Read Cycle) Initiate a read cycle to begin a conversion. A read cycle begins with the master issuing a START condition followed by seven address bits and a read bit (R/W). The standard I2C-compatible interface requires that R/W = 1 to read from a device, however, since the MAX1069 does not require setup or configuration, the read mode is inherent and R/W controls power-down (see the Internal Reference Shutdown section). If the address byte is successfully received, the MAX1069 (slave) issues an acknowledge and begins conversion. As seen in Figure 11, the MAX1069 holds SCL low dur- ing conversion. When the conversion is complete, SCL is released and the master can clock data out of the device. The most significant byte of the conversion is available first and contains D13 to D6. The least signifi- cant byte contains D5 to D0 plus two trailing sub bits S1 and S0. Data can be continuously converted as long as the master acknowledges the conversion results. Issuing a not acknowledge frees the bus allowing the master to generate a STOP or repeated START. Applications Information Power-On Reset When power is first applied, internal power-on reset cir- cuitry activates the MAX1069 in shutdown. When the internal reference is used, allow 12ms for the reference to settle when CREF = 10µF and CREFADJ = 0.1µF. Automatic Shutdown The MAX1069 automatic shutdown reduces the supply current to less than 0.6µA between conversions. The MAX1069 I2C-compatible interface is always active. When the MAX1069 receives a valid slave address the device powers up. The device is then powered down again when the conversion is complete. The automatic shutdown function does not change with internal or external reference. When the internal reference is cho- sen, the internal reference remains active between con- versions unless internal reference shutdown is requested (see the Internal Reference Shutdown section). Internal Reference Shutdown The R/W bit of the slave address controls the MAX1069 internal reference shutdown. In external reference mode (REFADJ = AVDD), R/W is a don’t care. In internal reference mode, setting R/W = 1 places the device in normal operation and setting R/W = 0 prepares the internal reference for shutdown. 58.6ksps, 14-Bit, 2-Wire Serial ADC in a 14-Pin TSSOP ______________________________________________________________________________________ 15 Figure 10. F/S-Mode to HS-Mode Transfer 123 0 0 0 89 45 67 01 X X X Sr S F/S-MODE HS-MODE SDA A Figure 9. MAX1069 Slave Address Byte SCL SDA 123 1 1 0 89 45 67 ADD3 ADD2 ADD1 ADD0 R/W A ACKNOWLEDGE S |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |