| Motore di ricerca datesheet componenti elettronici |
|
MASW-008853 Scheda tecnica(PDF) 2 Page - M/A-COM Technology Solutions, Inc. |
|
|
|||||||||||||||||||||||||||||
MASW-008853 Scheda tecnica(HTML) 2 Page - M/A-COM Technology Solutions, Inc. |
|
2 / 4 page ![]() GaAs SPDT 2.7 V High Power Switch DC - 5.0 GHz Rev. V2 MASW-008853 2 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support 2 Electrical Specifications: TA = 25°C, VC = 0 V/2.7 V, Z0 = 50 Ω 5 5. For positive voltage control, external DC blocking capacitors are required on all RF ports. 6. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 GHz - 3 GHz. Parameter Test Conditions Units Min. Typ. Max. Insertion Loss6 1 GHz 2 GHz 3 GHz 4 GHz 5 GHz dB dB dB dB dB — — — — — 0.30 0.36 0.45 0.70 1.10 0.65 — — — — Isolation 1 GHz 2 GHz 3 GHz 4 GHz 5 GHz dB dB dB dB dB 23 — — — — 25 19 15 13 11 — — — — — Return Loss DC – 3 GHz dB — 20 — IP3 825 MHz Two Tone, +24 dBm Total Pin, 5 MHz Spacing dBm — 56 — Cross Modulation Two-tone signal input: Tx1 = +22 dBm @ 820 MHz, Tx2 = +22 dBm @ 821 MHz, RX interfere = -23 dBm @ 869 MHz dBm — -99 — Two-tone signal input: Tx1 = +18 dBm @ 1880 MHz, Tx2 = +18 dBm @ 1881 MHz, RX interfere = -23 dBm @ 1960 MHz dBm — -94 — P0.1dB 1 GHz dBm — 38 — Trise, Tfall 10% to 90% RF, 90% to 10% RF nS — 70 — Ton, Toff 50% control to 90% RF, 50% control to 10% RF nS — 100 — Transients In Band mV — 25 — Control Current VC = 2.7 V µA — 5 20 Truth Table 7,8,9 7. For positive voltage control, external DC blocking capacitors are required on all RF ports. 8. Differential voltage, V(state 1) - V(state 0), must be +2.7 V minimum, but must not exceed 8.5 V. 9. 0 = -5 V to +2.3 V, 1 = -2.3 V to +5 V. V1 V2 ANT– RF1 ANT - RF2 1 0 On Off 0 1 Off On Qualification Qualified to M/A-COM specification REL-201, Process Flow –2. Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |