Back Button X9410 Datasheet HTML 3Page - Xicor Inc. X9410 Datasheet HTML 4Page - Xicor Inc. X9410 Datasheet HTML 5Page - Xicor Inc. X9410 Datasheet HTML 6Page - Xicor Inc. X9410 Datasheet HTML 7Page - Xicor Inc. X9410 Datasheet HTML 8Page - Xicor Inc. X9410 Datasheet HTML 9Page - Xicor Inc. X9410 Datasheet HTML 10Page - Xicor Inc. X9410 Datasheet HTML 11Page - Xicor Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 21 page
background image
X9410
Characteristics subject to change without notice.
7 of 21
REV 1.1 10/6/00
www.xicor.com
Figure 8. Increment/Decrement Timing Limits
Table 1. Instruction Set
Instruction
Instruction Set
Operation
I3
I2
I1
I0
R1 R0 P1 P0
Read Wiper Counter
Register
1001000
P0 Read the contents of the Wiper Counter Register
pointed to by P0
Write Wiper Counter
Register
1010000
P0 Write new value to the Wiper Counter Register
pointed to by P0
Read Data Register
1
0
1
1
R1
R0
0P0 Read the contents of the Data Register pointed to
by P0 and R1–R0
Write Data Register
1
1
0
0
R1
R0
0P0 Write new value to the Data Register pointed to
by P0 and R1–R0
XFR Data Register to
Wiper Counter Register
1101
R1
R0
0P0 Transfer the contents of the Data Register pointed
to by R1–R0 to the Wiper Counter Register pointed
to by P0
XFR Wiper Counter
Register to Data Register
1110
R1
R0
0P0 Transfer the contents of the Wiper Counter
Register pointed to by P0 to the Register pointed
to by R1–R0
Global XFR Data Register
to Wiper Counter Register
0001
R1
R0
0
0
Transfer the contents of the Data Registers
pointed to by R1–R0 of both pots to their
respective Wiper Counter Register
Global XFR Wiper
Counter Register to Data
Register
1000
R1
R0
0
0
Transfer the contents of all Wiper Counter
Registers to their respective data Registers
pointed to by R1–R0 of both pots
Increment/Decrement
Wiper Counter Register
0010000
P0 Enable Increment/decrement of the Wiper
Counter Register pointed to by P0
Read Status (WIP bit)
0
1
0
10001
Read the status of the internal write cycle, by
checking the WIP bit.
SCK
SI
VW/RW
INC/DEC CMD Issued
tWRID
Voltage Out



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com