125 / 223 page ![]() Application Notes AN1001 ©2002 Teccor Electronics AN1001 - 5 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 When voltage is impressed suddenly across a PN junction, a charging current flows, equal to: When becomes greater or equal to thyristor IGT, the thyristor switches on. Normally, this type of turn-on does not damage the device, providing the surge current is limited. Generally, thyristor application circuits are designed with static dv/dt snubber networks if fast-rising voltages are anticipated. Voltage Breakover Turn-on This method is used to switch on sidacs and diacs. However, exceeding voltage breakover of SCRs and triacs is definitely not recommended as a turn-on method. In the case of SCRs and triacs, leakage current increases until it exceeds the gate current required to turn on these gated thyris- tors in a small localized point. When turn-on occurs by this method, localized heating in a small area may melt the silicon or damage the device if di/dt of the increasing current is not suffi- ciently limited. Diacs used in typical phase control circuits are basically pro- tected against excessive current at breakover as long as the fir- ing capacitor is not excessively large. When diacs are used in a zener function, current limiting is necessary. Sidacs are typically pulse-firing, high-voltage transformers and are current limited by the transformer primary. The sidac should be operated so peak current amplitude, current duration, and di/dt limits are not exceeded. Triac Gating Modes Of Operation Triacs can be gated in four basic gating modes as shown in Figure AN1001.17. Figure AN1001.17 Gating Modes The most common quadrants for triac gating-on are Quadrants I and III, where the gate supply is synchronized with the main ter- minal supply (gate positive — MT2 positive, gate negative — MT2 negative). Gate sensitivity of triacs is most optimum in Quadrants I and III due to the inherent thyristor chip construction. If Quadrants I and III cannot be used, the next best operating modes are Quadrants II and III where the gate has a negative polarity supply with an AC main terminal supply. Typically, Quad- rant II is approximately equal in gate sensitivity to Quadrant I; however, latching current sensitivity in Quadrant II is lowest. Therefore, it is difficult for triacs to latch on in Quadrant II when the main terminal current supply is very low in value. Special consideration should be given to gating circuit design when Quadrants I and IV are used in actual application, because Quadrant IV has the lowest gate sensitivity of all four operating quadrants. General Terminology The following definitions of the most widely-used thyristor terms, symbols, and definitions conform to existing EIA-JEDEC stan- dards: Breakover Point – Any point on the principal voltage-current characteristic for which the differential resistance is zero and where the principal voltage reaches a maximum value Principal Current – Generic term for the current through the col- lector junction (the current through main terminal 1 and main ter- minal 2 of a triac or anode and cathode of an SCR) Principal Voltage – Voltage between the main terminals: (1) In the case of reverse blocking thyristors, the principal volt- age is called positive when the anode potential is higher than the cathode potential and negative when the anode potential is lower than the cathode potential. (2) For bidirectional thyristors, the principal voltage is called positive when the potential of main terminal 2 is higher than the potential of main terminal 1. Off State – Condition of the thyristor corresponding to the high- resistance, low-current portion of the principal voltage-current characteristic between the origin and the breakover point(s) in the switching quadrant(s) On State – Condition of the thyristor corresponding to the low- resistance, low-voltage portion of the principal voltage-current characteristic in the switching quadrant(s). Specific Terminology Average Gate Power Dissipation [PG(AV)] – Value of gate power which may be dissipated between the gate and main terminal 1 (or cathode) averaged over a full cycle Breakover Current (IBO) – Principal current at the breakover point Breakover Voltage (VBO) – Principal voltage at the breakover point Circuit-commutated Turn-off Time (tq) – Time interval between the instant when the principal current has decreased to zero after external switching of the principal voltage circuit and the instant when the thyristor is capable of supporting a specified principal voltage without turning on Critical Rate-of-rise of Commutation Voltage of a Triac (Commutating dv/dt) – Minimum value of the rate-of-rise of prin- cipal voltage which will cause switching from the off state to the on state immediately following on-state current conduction in the opposite quadrant iC dv dt ------ èø æö = C dv dt ------ èø æö MT2 POSITIVE (Positive Half Cycle) MT2 NEGATIVE (Negative Half Cycle) MT1 MT2 + I GT REF QII MT1 I GT GATE MT2 REF MT1 MT2 REF MT1 MT2 REF QI QIV QIII ALL POLARITIES ARE REFERENCED TO MT1 ( -) I GT GATE (+) I GT - I GT GATE ( -) I GT GATE (+) + - NOTE: Alternistors will not operate in Q IV |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |