Back Button EVAL-AD7734EBZ Datasheet HTML 25Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 26Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 27Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 28Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 29Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 30Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 31Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 32Page - Analog Devices EVAL-AD7734EBZ Datasheet HTML 33Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 31 / 33 page
background image
AD7734
Data Sheet
Rev. B | Page 30 of 32
I/O PORT
The AD7734 P0 pin can be used as a general-purpose digital
I/O pin. The P1 pin (SYNC/P1) can be used as a general-purpose
digital I/O pin or to synchronize the AD7734 with other devices
in the system. When the SYNC bit in the I/O port register is set and
the SYNC pin is low, the AD7734 does not process any conversion.
If it is put into single conversion mode, continuous conversion
mode, or any calibration mode, the AD7734 waits until the SYNC
pin goes high and then starts operation. This allows conversion
to start from a known point in time, that is, the rising edge of
the SYNC pin.
The digital P0 and P1 voltage is referenced to the analog supplies.
When configured as inputs, the pins should be tied high or low.
CALIBRATION
The AD7734 provides zero-scale self-calibration, and zero-scale
and full-scale system calibration capability that can effectively
reduce the offset error and gain error to the order of the noise.
After each conversion, the ADC conversion result is scaled
using the ADC calibration registers and the relevant channel
calibration registers before being written to the data register.
For unipolar ranges:
Data = ((ADC result – ADC ZS Cal. reg.) ×
ADC FS Reg./200000h – Ch. ZS Cal. reg.) ×
Ch. FS Cal. reg./200000h
For bipolar ranges:
Data = ((ADC result – ADC ZS Cal. reg.) ×
ADC FS Reg./400000h + 800000h – Ch. ZS Cal. reg.)
× Ch. FS Cal. reg./200000h
Where the ADC result is in the range of 0 to FFFFFFh.
Note that the channel zero-scale calibration register has the
format of a sign bit and a 22-bit channel offset value.
It is strongly recommended that the user not change the ADC
full-scale register.
To start any calibration, write the relevant mode bits to the
AD7734 mode register. After the calibration is complete, the
contents of the corresponding calibration registers are updated,
all RDY bits in the ADC status register are set, the SYNC pin
goes low, and the AD7734 reverts to idle mode. The calibration
duration is the same as the conversion time configured on the
selected channel. A longer conversion time gives less noise and
yields a more exact calibration; therefore, use at least the default
conversion time to initiate any calibration.
ADC ZERO-SCALE SELF-CALIBRATION
The ADC zero-scale self-calibration can reduce the offset error
in the chopping disabled mode. If repeated after a temperature
change, it can also reduce the offset drift error in the chopping
disabled mode.
The zero-scale self-calibration is performed on internally shorted
ADC inputs. The negative analog input terminal on the selected
channel is used to set the ADC zero-scale calibration common
mode. Therefore, either the negative terminal of the selected
differential pair or the AINCOM on the single-ended channel
configuration should be driven to a proper common-mode
voltage.
It is strongly recommended that the ADC zero-scale calibration
register should only be updated as part of a zero-scale self-
calibration.
PER CHANNEL SYSTEM CALIBRATION
If the per channel system calibrations are used, these should be
initiated in the following order: a channel zero-scale system
calibration, followed by a channel full-scale system calibration.
The system calibration is affected by the ADC zero-scale and full-
scale calibration registers. Therefore, if both self-calibration and
system calibration are used in the system, an ADC full-scale
self-calibration should be performed first, followed by a system
calibration cycle.
While executing a system calibration, the fully settled system zero-
scale voltage signal or system full-scale voltage signal must be
connected to the selected channel analog inputs.
The per channel calibration registers can be read, stored, or
modified and written back to the AD7734. Note that when
writing the calibration registers the AD7734 must be in idle
mode. Note that outside the specified calibration range,
calibration is possible but the performance may degrade (see
the System Calibration parameter in Table 1).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com