| Motore di ricerca datesheet componenti elettronici |
|
ACPL-P302 Scheda tecnica(PDF) 4 Page - Broadcom Corporation. |
|
|
|||||||||||||||||||||||||||||
ACPL-P302 Scheda tecnica(HTML) 4 Page - Broadcom Corporation. |
|
4 / 15 page ![]() Broadcom Confidential - 4 - ACPL-P302/ACPL-W302 Data Sheet Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used. Regulatory Information The ACPL-P302/W302 is approved by the following organizations: UL Approval under UL 1577 component recognition program up to VISO = 3750VRMS for the ACPL-P302 and VISO = 5000VRMS for the ACPL-W302, File E55361. CSA CSA Component Acceptance Notice #5, File CA 88324 IEC/EN/DIN EN 60747-5-5 (Option 060 Only) Approval under: IEC 60747-5-5:2007 IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060) Description Symbol ACPL- W302 ACPL- P302 Unit Installation classification per DIN VDE 0110/39, Table 1 for rated mains voltage ≤ 150VRMS for rated mains voltage ≤ 300VRMS for rated mains voltage ≤ 450VRMS for rated mains voltage ≤ 600VRMS for rated mains voltage ≤ 1000VRMS I-IV I-IV I-IV I-IV I-III I-IV I-IV I-III I-III Climatic Classification 55/100/21 55/100/21 Pollution Degree (DIN VDE 0110/39) 2 2 Maximum Working Insulation Voltage VIORM 1140 891 Vpeak Input to Output Test Voltage, Method b* VIORM × 1.875 = VPR, 100% Production Test with tm =1 sec, Partial discharge < 5 pC VPR 2137 1670 Vpeak Input to Output Test Voltage, Method a* VIORM × 1.6 = VPR, Type and Sample Test, tm =10 sec, Partial discharge < 5 pC VPR 1824 1426 Vpeak Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec) VIOTM 8000 6000 Vpeak Safety-limiting values – maximum values allowed in the event of a failure Case Temperature TS 175 175 °C Input Current IS, INPUT 230 230 mA Output Power PS, OUTPUT 600 600 mW Insulation Resistance at TS, VIO = 500V RS ≤109 ≤109 Ω * Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Broadcom Regulatory Guide to Isolation Circuits, AV02-2041EN for a detailed description of Method a and Method b partial discharge test profiles. ** Refer to the following figure for dependence of PS and IS on ambient temperature. 0 0 TS – CASE TEMPERATURE – °C 200 600 400 25 800 50 75 100 200 150 175 PS (mW) 125 100 300 500 700 IS (mA) |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |