| Motore di ricerca datesheet componenti elettronici |
|
TLE5014 Scheda tecnica(PDF) 21 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE5014 Scheda tecnica(HTML) 21 Page - Infineon Technologies AG |
|
21 / 45 page ![]() Final Datasheet 21 Rev. 1.0 2018-04-04 TLE5014 Specification 3.4 EEPROM Memory The sensor includes a non-volatile memory (NVM) where calibration data and sensor configuration data are stored. The customer has access to a part of this memory for storage of application specific data (e.g. look-up table & customer ID) The time for programming the customer relevant part of the NVM as well as maximum cycles of programming and data retention is given in Table 3-13 3.5 Reset Concept and Fault Monitoring Some internal and external faults of the device can trigger a reset. During this reset, all output pins are high- ohmic to avoid any disturbance of other sensors which may be connected together in a bus mode. A reset is indicated as soon as the sensor is back at operational mode either by a status bit (SPC and SENT protocol) or with a duty cycle in the diagnostic range (PWM interface). In the case of a periodic reset (sensor toggles between on and off state) it is avoided that the output toggles with a frequency close to a valid PWM frequency. In this way it is ensured, that a reset can clearly be distinguished from a valid output signal. 3.6 External & Internal Faults In case of an occurrence of external or internal faults, as for example overvoltage or undervoltage, the sensor reacts in a way that these faults are indicated to the customer. This can be either by a status bit (SPC and SENT protocol) or with a duty cycle in the diagnostic range (PWM interface). The error signaling (safe state) is defined as: • indication of an error (e.g. status bit) • detectable wrong output (e.g. CRC failure) • no output All errors are indicated as long as they persist, but at least once. After disappearance of the error, the error indication is also cleared. The error is signaled and communicated to the ECU latest after 5ms from occurrence of the fault. To achieve this, it has to be ensured that the protocol transmission time is not exceeding 1ms. Otherwise, the fault tolerant time interval is increased above 5ms. 5) Hysteresis is the maximum difference of the angle value for forward and backward rotation 6) For the magnetic field range of 25mT < B < 33mT, 0.1° have to be added to the max. hysteresis AHyst Table 3-13 EEPROM Parameter Symbol Values Unit Note / Test Condition Number Min. Typ. Max. Number of possible NVM programming cycles nProg 100 - NVM data retention tretention - 21 a includes 19a lifetime and 2a storage Time for programming of whole NVM (customer relevant part) tProg 0.5 s incl. look-up table, configuration, customer ID; with 100kbit/s |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |