| Motore di ricerca datesheet componenti elettronici |
|
2403678 Scheda tecnica(PDF) 7 Page - PHOENIX CONTACT |
|
|
|||||||||||||||||||||||||||||
2403678 Scheda tecnica(HTML) 7 Page - PHOENIX CONTACT |
|
7 / 12 page ![]() AXC F XT ETH 1TX 107237_en_01 PHOENIX CONTACT 7 / 12 7Mounting 7.1 Removing the controller supply connector • Release the locking latch (A), tilt the supply connector upwards slightly (B), and remove it from the controller (C). Figure 3 Removing the supply connector 7.2 Removing other connectors from the controller • Remove all other connectors from the controller. 7.3 Removing electronics modules Before the left-alignable Ethernet interface can be aligned to the controller, you must remove the controller electronics module. In the case of AXC ... controllers, you must also remove the electronics module of the first module aligned to the right. To do this, proceed as follows: • Insert a suitable tool (e.g., bladed screwdriver) into the upper and lower snap-on mechanisms (base latches) of the controller/module one after the other and release it (A). The base latches are locked in place in the open position. • Remove the electronics module vertically out of the DIN rail (B). Figure 4 Removing the electronics module To operate the left-alignable Ethernet interface on a controller for Axioline F, a special bus base module is required for the respective controller. The bus base module is not supplied as standard with AXC ... controllers. For the ordering data, please refer to the user manual for the controller you are using. In the case of AXC ... controllers, you must first replace the existing bus base module with the special bus base module. To do this, proceed as follows: • Remove the controller bus base module from the bus base of the first module aligned to the right. • Remove the controller bus base module from the DIN rail. Proceed as follows to mount the special bus base module: Please note: Mount all the modules required before supplying power to the Axioline F station. Modules to which power is only supplied following the controller boot process are not detected or may result in a malfunction. To ensure that the left-alignable Ethernet interface is detected correctly, proceed as follows: – Switch on the power to the left-alignable Ethernet interface before switching on the power to the controller OR – Switch on the power to the left-alignable Ethernet interface and to the controller simultaneously. A A B |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |