126 / 197 page ![]() 1. This field is optional. Response parameters: • Block security status if Option_flag is set (see Table 219. Block security status) • Four bytes of block data Table 219. Block security status b7 b6 b5 b4 b3 b2 b1 b0 Reserved for future use All at 0 0: Current Block not locked 1: Current Block locked Table 220. Fast Extended Read Single Block response format when Error_flag is set Response SOF Response_flags Error code CRC16 Response EOF - 8 bits 8 bits 16 bits - Response parameter: • Error code as Error_flag is set: – 02h: command not recognized – 03h: command option not supported – 0Fh: error with no information given – 10h: the specified block is not available – 15h: the specified block is read-protected Figure 67. Fast Extended Read Single Block frame exchange between VCD and ST25DVxxx SOF Fast Extended Read Single Block request VCD ST25DVxxx EOF SOF Fast Extended Read Single Block response EOF t1 7.6.39 Fast Read Multiple Blocks On receiving the Fast Read Multiple Blocks command, the ST25DVxxx reads the selected blocks and sends back their value in multiples of 32 bits in the response. The blocks are numbered from 00h up to the last block of user memory in the request, and the value is minus one (–1) in the field. For example, if the “Number of blocks” field contains the value 06h, seven blocks are read. The maximum number of blocks is fixed to 256 assuming that they are all located in the same area. If the number of blocks overlaps area or overlaps the end of user memory, the ST25DVxxx returns an error code. When the Option_flag is set, the response includes the Block Security Status. The data rate of the response is multiplied by 2. The subcarrier_flag should be set to 0, otherwise the ST25DVxxx answers with an error code. The Inventory_flag must be set to 0. Block number is coded on 1 Byte and only first 256 blocks of ST25DV16K-xx and ST25DV64K-xx can be addressed using this command. ST25DV04K ST25DV16K ST25DV64K RF commands DS10925 - Rev 11 page 126/197 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |