| Motore di ricerca datesheet componenti elettronici |
|
L9965P-FN Scheda tecnica(PDF) 58 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9965P-FN Scheda tecnica(HTML) 58 Page - STMicroelectronics |
|
58 / 104 page ![]() 3.8.1 Measurement trigger modes The ADC supports three different conversion execution modes: • On-Demand, triggered by MCU writing ADC_CONV_CMD bit equal to 1 and configuring the input channel with the AMUX_CONF bit field in the same command frame (see the Table 31): – This type of request does not move the FSM to DIAG state. – Results of the on-demand ADC conversions are available in the ADC_CONV_RESULT register when ADC_CONV_RDY bit is set to 1. – If the ADC is just busy, the ADC_BUSY bit is set to 1. • Cyclically: – In full-power mode (CWUP = 1, static), the diagnostic routine runs every tDIAG_ROUTINE_PERIOD. The voltage ADC is involved in some diagnostic steps (if such steps are enabled). – In low-power mode (periodic CWUP pulses), the diagnostic routine is executed at every wake ‑up. – These types of requests move the FSM to DIAG state. • Asynchronously: – If the FSM moves to the ARM state, the ADC is used for post-deployment resistance measurement if selected as the FIRE_GOOD source. – The result of this conversion is reported in the RES_MEAS_POST register. Conflict between multiple triggers is managed as follows: • If the FSM is in DIAG state (either triggered by CWUP in low-power mode or triggered by the MCU in full- power mode), on-demand triggers are discarded. Note: When in low-power mode, the FSM moves to DIAG upon cyclic powerups. Hence, the cyclic execution of the diagnostic routine is guaranteed by design. • If an on-demand conversion is being performed, the cyclic execution of the diagnostic routine is skipped and it will be performed upon the next useful trigger period. • In any case, if the FSM moves to the ARM state, any ongoing conversion is interrupted and the ADC will be set up for post-deployment resistance measurement. This deployment trigger has the highest priority. Table 31. ADC input channel selection for on-demand conversions AMUX_CONF Channel 000 PS vs PGND 001 PF vs PGND 010 PR vs PGND 011 PF vs PR (high resolution - pre deployment) 100 PF vs PR (low resolution - post deployment) 101 ERBST vs GNDx 110 VRCM vs PGND 111 Not used The ADC LSB is rescaled according to the selected channel and to the diagnostic steps. L9965P Functional description DS14702 - Rev 4 page 58/104 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |