7 / 50 page ![]() 6.5 Electrical Characteristics over recommended operating free-air temperature range, VCCI = 1.65 V to 5.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS VCCP MIN TYP(1) MAX UNIT VIK Input diode clamp voltage II = –18 mA 1.65 V to 5.5 V –1.2 V VPOR Power-on reset voltage(2) VI = VCCP or GND, IO = 0 1.65 V to 5.5 V 1 1.4 V VOH P-port high-level output voltage IOH = –8 mA 1.65 V 1.2 V 2.3 V 1.8 3 V 2.6 4.5 V 4.1 IOH = –10 mA 1.65 V 1.1 2.3 V 1.7 3 V 2.5 4.5 V 4.0 VOL P-port low-level output voltage IOL = 8 mA 1.65 V 0.45 V 2.3 V 0.25 3 V 0.25 4.5 V 0.2 IOL = 10 mA 1.65 V 0.6 2.3 V 0.3 3 V 0.25 4.5 V 0.2 IOL SDA VOL = 0.4 V 1.65 V to 5.5 V 3 mA INT 3 15 II SCL, SDA, RESET VI = VCCI or GND 1.65 V to 5.5 V ±0.1 μA ADDR VI = VCCP or GND ±0.1 IIH P-port VI = VCCP 1.65 V to 5.5 V 1 μA IIL P-port VI = GND 1 μA ICC (ICCI + ICCP) Operating mode SDA, P-port, ADDR, RESET VI on SDA and RESET= VCCI or GND, VI on P-port and ADDR = VCCP or GND, IO = 0, I/O = inputs, fSCL = 400 kHz 3.6 V to 5.5 V 10 20 μA 2.3 V to 3.6 V 6.5 15 1.65 V to 2.3 V 4 9 Standby mode SCL, SDA, P-port, ADDR, RESET VI on SCL, SDA and RESET = VCCI or GND, VI on P-Port and ADDR = VCCP or GND, IO = 0, I/O = inputs, fSCL = 0 3.6 V to 5.5 V 1.5 7 2.3 V to 3.6 V 1 3.2 1.65 V to 2.3 V 0.5 1.7 ΔICCI Additional current in standby mode SCL, SDA, RESET One input at VCCI – 0.6 V, Other inputs at VCCI or GND 1.65 V to 5.5 V 25 μA ΔICCP P-port, ADDR One input at VCCP – 0.6 V, Other inputs at VCCP or GND 1.65 V to 5.5 V 80 μA Ci SCL VI = VCCI or GND 1.65 V to 5.5 V 6 7 pF Cio SDA VIO = VCCI or GND 1.65 V to 5.5 V 7 8 pF P-port VIO = VCCP or GND 7.5 8.5 (1) All typical values are at nominal supply voltage (1.8-V, 2.5-V, 3.3-V, or 5-V VCC) and TA = 25°C. (2) When power (from 0 V) is applied to VCCP, an internal power-on reset holds the TCA6408A in a reset condition until VCCP has reached VPOR. At that time, the reset condition is released, and the TCA6408A registers and I2C/SMBus state machine initialize to their default states. After that, VCCP must be lowered to below 0.2 V and back up to the operating voltage for a power-reset cycle. www.ti.com TCA6408A SCPS192E – APRIL 2009 – REVISED JANUARY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: TCA6408A |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |