| Motore di ricerca datesheet componenti elettronici |
|
CDPCLK7 Scheda tecnica(PDF) 242 Page - Altera Corporation |
|
|
|||||||||||||||||||||||||||||
CDPCLK7 Scheda tecnica(HTML) 242 Page - Altera Corporation |
|
242 / 274 page ![]() 9–84 Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family Remote System Upgrade Cyclone III Device Handbook August 2012 Altera Corporation Volume 1 Table 9–29 lists the contents of the previous state register 1 and previous state register 2 in the status register when the MSEL pin setting is set to the AS or AP scheme. The status register bit in Table 9–29 shows the bit positions in a 31-bit register. The previous state register 1 and previous state register 2 have the same bit definitions. The previous state register 1 reflects the current application configuration and the previous state register 2 reflects the previous application configuration. If a capture is inappropriately done, for example, capturing a previous state before the system has entered remote update application configuration for the first time, a value will output from the shift register to indicate that the capture was incorrectly called. Remote System Upgrade State Machine The remote system upgrade control and update registers have identical bit definitions, but serve different roles (Table 9–26 on page 9–81). While both registers can only be updated when the device is loaded with a factory configuration image, the update register writes are controlled by the user logic, and the control register writes are controlled by the remote system upgrade state machine. In factory configurations, the user logic should send the option bits (Cd_early and Osc_int ), the configuration address, and watchdog timer settings for the next application configuration bit to the update register. When the logic array configuration reset (RU_nCONFIG) goes high, the remote system upgrade state machine updates the control register with the contents of the update register and starts system reconfiguration from the new application page. Table 9–29. Remote System Upgrade Previous State Register 1 and Previous State Register 2 Contents in Status Register (1) Status Register Bit Definition Description 30 nCONFIG source One-hot, active-high field that describes the reconfiguration source that caused the Cyclone III device family to leave the previous application configuration. If there is a tie, the higher bit order indicates precedence. For example, if nCONFIG and remote system upgrade nCONFIG reach the reconfiguration state machine at the same time, the nCONFIG precedes the remote system upgrade nCONFIG. 29 CRC error source 28 nSTATUS source 27 User watchdog timer source 26 Remote system upgrade nCONFIG source 25:24 Master state machine current state The state of the master state machine during reconfiguration causes the Cyclone III device family to leave the previous application configuration. 23:0 Boot address The address used by the configuration scheme to load the previous application configuration. Note to Table 9–29: (1) The MSEL pin settings are in the AS configuration scheme. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |