| Motore di ricerca datesheet componenti elettronici |
|
ADM1026JSTZ-R7 Scheda tecnica(PDF) 44 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADM1026JSTZ-R7 Scheda tecnica(HTML) 44 Page - ON Semiconductor |
|
44 / 55 page ![]() ADM1026 http://onsemi.com 44 Table 47. REGISTER 21H, STATUS REGISTER 2 (POWER-ON DEFAULT, 00H) Bit Name R/W Description 0 AIN0 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 1 AIN1 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 2 AIN2 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 3 AIN3 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 4 AIN4 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 5 AIN5 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 6 AIN6 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. 7 AIN7 Status = 0 R 1, if AIN0 to AIN7 value is above the high limit or below the low limit on the previous conversion cycle; 0 otherwise. Table 48. REGISTER 22H, STATUS REGISTER 3 (POWER-ON DEFAULT, 00H) Bit Name R/W Description 0 FAN0 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 1 FAN1 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 2 FAN2 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 3 FAN3 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 4 FAN4 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 5 FAN5 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 6 FAN6 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. 7 FAN7 Status 1 = 0 R 1, if FAN0 to FAN7 value is above the high limit on the previous conversion cycle; 0 otherwise. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |