| Motore di ricerca datesheet componenti elettronici |
|
ML7344J Scheda tecnica(PDF) 95 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ML7344J Scheda tecnica(HTML) 95 Page - List of Unclassifed Manufacturers |
|
95 / 151 page ![]() FEDL7344C/E/J-04 ML7344C/E/J 95/151 In actual operation, based on the 2 compensation values for each TX/RX, the most optimized capacitance value for the frequency is calculated and applied. The calculated value is stored in [VCO_CAL: B0 0x6E]. By evaluation stage, if below values are stored in the MCU memory and uses these values upon reset or power-up, calibration operation can be omitted. Registers to be saved in the MCU memory. [VCO_CAL_MIN_I: B1 0x4D] [VCO_CAL_MIN_FH: B1 0x4E] [VCO_CAL_MIN_FM: B1 0x4F] [VCO_CAL_MIN_FL: B1 0x50] [VCO_CAL_MAX_N: B1 0x51] [TXVCAL_MIN: B1 0x52] [TXVCAL_MAX: B1 0x53] [RXVCAL_MIN: B1 0x54] [RXVCAL_MAX: B1 0x55] After issuing VCO calibration, VCO tuning voltage may be out of control range by the temperature difference between operating timing and VCO calibration timing. If activating RF when VCO tuninng voltage is out of control range, the margine of VCO operation will be lost and it may cause the PLL unlock. When detecting VCO tuning voltage is out of control range, VCO calibration should be re-issued or set VCO caluibration value which has operating margine at that temperature. The ML7344 has the function of comparing the VCO tunign voltage with upper and lower limit voltages and determining it is in the control range or not and indiacting the result. After detecting VCO tuning voltage is out of contol range, it can be notified by INT[2] (group1: VCO CAL request interrupt). [Relative controlo bit] The comparison result with maximum threshold: VTUNE_COMP_H ([VCO_VTRSLT:B0 0x40(1)]) The comparison result with minimum threshold: VTUNE_COMP_L ([VCO_VTRSLT:B0 0x40(0)]) VCO CAL request interrupt enable setting: VTUNE_INT_ENB ([VCO_VTRSLT:B0 0x40(2)]) State control after PLL unlock detection: PLL_LD_EN ([PLL_LOCK_DETECT:B1 0x0B(7)] [VCO voltage condition] VTUNE_COMP_L [VCO_VTRSLT:B0 0x40(0)] VTUNE_COMP_H [VCO_VTRSLT:B0 0x40(1)] Condition 0b0 0b0 Ordinary 0b0 0b1 Out of control range (beyond upper level) 0b1 0b0 Out of control range (below lower level) 0b1 0b1 Extra ordinary NOTE: 1. For low limit frequency, please use frequency at least 400kHz lower than operation frequency 2. For upper limit frequency should be selected so that operation frequency is in the frequency range. 3. In case of like a channel change, if the setting frequency is outside of calibration frequency range, calibration process has to be performed again with proper frequency. 4. INT[2] (group1) will generate by detecting PLL unlock or VCO CAL request (when VTUNE_INT_ENB ([VCO_VTRSLT:B0 0x40(2)])=0b1). The following shows the ML7344 opereation related with LSI state and PLL_LD_EN([PLL_LOCK_DETECT:B1 0x0B(7)]) setting, after interrupt generation. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |