Back Button HTG12N0 Datasheet HTML 20Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 21Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 22Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 23Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 24Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 25Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 26Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 27Page - Holtek Semiconductor Inc HTG12N0 Datasheet HTML 28Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 30 page
background image
MOV A,XH
Move immediate data to accumulator
Machine Code
0 1 1 1 d d d d
Description
The 4-bit data specified by code is loaded to the accumulator.
Operation
ACC
XH
MOV A,[R1R0]
Move data memory to accumulator
Machine Code
0 0 0 0 0 1 0 0
Description
Data in the data memory specified by the register pair “R1,R0” is moved to
the accumulator.
Operation
ACC
M(R1,R0)
MOV A,[R3R2]
Move data memory to accumulator
Machine Code
0 0 0 0 0 1 1 0
Description
Data in the data memory specified by the register pair “R3,R2” is moved to
the accumulator.
Operation
ACC
M(R3,R2)
MOV R1R0,XXH
Move immediate data to R1 and R0
Machine Code
0 1 0 1 d d d d
0 0 0 0 d d d d
Description
The 8-bit data specified by code are loaded to the working registers R1 and
R0, the high nibble of the data is loaded to the R1, and the low nibble of
the data is loaded to the R0.
Operation
R1
XH (high nibble)
R0
XH (low nibble)
MOV R3R2,XXH
Move immediate data to R3 and R2
Machine Code
0 1 1 0 d d d d
0 0 0 0 d d d d
Description
The 8-bit data specified by code are loaded to the working register R3 and
R2, the high nibble of the data is loaded to the R3, and the low nibble of
the data is loaded to the R2.
Operation
R3
XH (high nibble)
R2
XH (low nibble)
MOV R4,XH
Move immediate data to R4
Machine Code
0 1 0 0 0 1 1 0
0 0 0 0 d d d d
Description
The 4-bit data specified by code are loaded to the working register R4.
Operation
R4
XH
HTG12N0
24
18th Mar ’99



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com