14 / 23 page ![]() TriPle OuTPuT MOdel – MHF+28515T 5 2 (Main) ±15 (auXiliarieS) uniTS ParaMeTer COndiTiOnS Min TYP MaX Min TYP MaX oUTpUT VolTAge VOuT 4.85 5.00 5.15 14.40 15.00 15.60 V OuTPuT CurrenT 3 eiTHer OuTPuT — — 1.5 0 ±0.250 0.333 1 a Vin = 16 TO 48 V TOTal — — 1.5 — — 0.500 OuTPuT POWer 4 eiTHer OuTPuT — — 7.5 — ±3.75 5 1 W Vin = 16 TO 48 V TOTal — — — — — 7.5 OuTPuT riPPle TC = 25°C — 20 60 — ±30 ±112 mV p-p 10 kHz - 2 MHz TC = -55°C TO +125°C — — 90 — — ±225 line regulaTiOn Vin = 16 TO 48 V — 25 75 — ±150 ±300 mV lOad regulaTiOn 5 nO lOad TO Full — 25 75 — ±150 ±300 mV CrOSS regulaTiOn 6 TC = 25°C eFFeCT on negATIVe auXiliarY — — — — — 750 mV InpUT VolTAge COnTinuOuS 16 28 48 — — — V TranSienT 1 120 ms — — 80 — — — V inPuT CurrenT nO lOad — 30 45 — — — ma inHiBiTed — 3 5 — — — inPuT riPPle CurrenT 3 10 kHz - 10 MHz — 20 50 — — — ma p-p eFFiCienCY TC = 25°C 74 76 — — — — % TC = -55°C TO +125°C 72 — — — — — lOad FaulT 7, 8 POWer diSSiPaTiOn SHOrT CirCuiT — — 12 — — ±12 W ReCoVeRY 1 — — 25 — — 25 ms STeP lOad reSPOnSe 9, 10 TranSienT — — ±850 — — ±950 mV pk ReCoVeRY — 5 8 — 2 3 ms STeP line reSPOnSe 1, 9, 11 TranSienT — — ±800 — — ±800 mV pk Vin = 16 - 40 - 16 V ReCoVeRY — — 5 — — 5 ms STarT-uP 12 delaY nO lOad and Full — 10 25 — 10 25 ms oVeRSHooT 1 — — 500 — — ±500 mV pk notes 1. guaranteed by qualification test and/or analysis. not an in-line test. 2. If running with external sync, at temperature extremes VOuT main may be a minimum of 4.80 volts to a maximum of 5.20 volts. 3. The sum of the 15 volt auxiliary output currents may not exceed 500 mA. 4. The sum of the auxiliary output power may not exceed 7.5 watts. Up to 5 watts (approximately 66%) of the total auxiliary output power is available from either output providing the opposite output is simultaneously carrying 2.5 watts (approximately 33%) of the total auxiliary power. 5. load regulation for the +5 is specified at 0.0 to 1.5 A with both auxiliaries held at 3.75 W (250 mA). load regulation for the auxiliary. is specified as both auxiliaries from 0.0 to 3.75 W (250 mA) at the same time with the +5 held at 1.5 a. 6. Cross regulation only occurs between the two auxiliaries and is measured on –aux. +5 is held constant at 1.0 A. Cross regulation is specified for two conditions: negative aux.= 3.76 W; positive aux.= 0.37 W to 3.76 W. negative aux. = 0.37 W to 3.76 W; positive aux. = 3.76 W. 7. load fault = < 0.100 Ω. 8. indefinite short circuit protection not guaranteed above 125°C case. 9. Time to settle to within 1% of VOuT final value. 10. Step transition time > 10 µs. 11. Step transition time 100 µs ±20%. 12. Measured on release from inhibit. table 11: eleCtriCal CharaCteristiCs -55°C to +125°C Case, 28 vin, 100% loaD, Free run, unless otherwise sPeCiFieD. www.craneae.com/interpoint Page 14 of 23 Crane Aerospace & Electronics Power Solutions mHF+ Single, Dual and Triple DC-DC Converters 28 VOlT INPuT – 15 WaTT MHF+ rev aB - 2014.10.02 |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |