| Motore di ricerca datesheet componenti elettronici |
|
AC08FSM Scheda tecnica(PDF) 167 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
AC08FSM Scheda tecnica(HTML) 167 Page - Teccor Electronics |
|
167 / 223 page ![]() Application Notes AN1006 ©2002 Teccor Electronics AN1006 - 15 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 To continue testing, perform the following procedures. Procedure 9: VTM(Forward) To measure the VTM (Forward) parameter: 1. Set Left-Right Terminal Jack Selector to correspond with the location of the test fixture. 2. Increase Variable Collector Supply Voltage until current reaches rated IT(peak), which is 1.4 times the IT(RMS) rating of the sidac. Note: Model 370 current is limited. Set to 400 mA. Check for 1.1 V MAX. WARNING: Limit test time to 15 seconds. 3. To measure VTM, follow along horizontal scale to the point where the trace crosses the IT(peak) value. This horizontal dis- tance is the VTM value. (Figure AN1006.25) Figure AN1006.25 VTM (Forward) = 950 mV at IPK = 1.4 A Procedure 10: VTM(Reverse) To measure the VTM (Reverse) parameter: 1. Set Polarity to (–). 2. Repeat Procedure 8 to measure VTM(Reverse). Diacs Diacs are voltage breakdown switches used to trigger-on triacs and non-sensitive SCRs in phase control circuits. Note: Diacs are bi-directional devices and can be connected in either direction. To connect the diac: 1. Connect one side of the diac to the Collector Terminal (C). 2. Connect other side of the diac to the Emitter Terminal (E). To begin testing, perform the following procedures. Procedure 1: Curve Tracer Setup To set the curve tracer and begin testing: 1. Set Variable Collector Supply Voltage Range to 75 Max Peak Volts. (80 V on 370) 2. Set Horizontal knob to sufficient scale to allow viewing of trace at the required voltage level (10 V to 20 V/DIV depend- ing on device being tested). 3. Set Vertical knob to 50 µA/DIV. 4. Set Polarity to AC. 5. Set Mode to Norm. 6. Set Power Dissipation to 0.5 W. (0.4 W on 370) 7. Set Terminal Selector to Emitter Grounded-Open Base. Procedure 2: VBO To measure the VBO parameter: 1. Set Left-Right Terminal Jack Selector to correspond with the location of the test fixture. 2. Set Variable Collector Supply Voltage to 55 V (65 V for 370) and apply voltage to device under test (D.U.T.), using Left-Right-Selector Switch. The peak voltage at which cur- rent begins to flow is the VBO value. (Figure AN1006.26) Figure AN1006.26 (+)VBO = 35 V; (-)VBO = 36 V; (±)IBO < 15 µA; (-)IBO < 10 µA and Cannot Be Read Easily Procedure 3: IBO To measure the IBO parameter, at the VBO point, measure the amount of device current just before the device reaches the breakover mode. The measured current at this point is the IBO value. Note: If IBO is less than 10 µA, the current cannot readily be seen on the curve tracer. Procedure 4: ∆VBO(Voltage Breakover Symmetry) To measure the ∆VBO (Voltage Breakover Symmetry) parameter: 1. Measure positive and negative values of VBO as shown in Figure AN1006.26. 2. Subtract the absolute value of VBO(-) from VBO(+). The absolute value of the result is: ∆VBO = [ I +VBO I - I -VBO I ] 500 mA 500 mV PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV VTM IPK 50 A 10 V PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV +VBO +IBO IBO VBO |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |