165 / 223 page ![]() Application Notes AN1006 ©2002 Teccor Electronics AN1006 - 13 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 Procedure 11: IH(Forward and Reverse) For these steps, it is again necessary to connect the Trigger to MT2 through a 10 Ω resistor. The other connections remain the same. To measure the IH (Forward and Reverse) parameter: 1. Set Power Dissipation to 50 W. 2. Set Max Peak Volts to 75 V. (80 V on 370) 3. Set Mode to DC. 4. Set Horizontal knob to 5 V/DIV. 5. Set Vertical knob to approximately 10% of the maximum IH specified. Note: Due to large variations of holding current values, the scale may have to be adjusted to observe holding current. 6. Set Terminal Selector to Emitter Grounded-Open Base. Procedure 12: IH(Forward) To measure the IH (Forward) parameter: 1. Set Polarity to (+). 2. Set Left-Right Terminal Jack Selector to correspond with the location of the test fixture. 3. Increase Variable Collector Supply Voltage to maximum position (100). Note: Depending on the vertical scale being used, the dot may disappear completely from the screen. 4. Decrease Variable Collector Supply Voltage to the point where the line on the CRT changes to a dot. The position of the beginning point of the line, just before the line changes to a dot, represents the IH value. (Figure AN1006.21) Figure AN1006.21 IH (Forward) = 18 mA Procedure 13: IH(Reverse) To measure the IH (Reverse) parameter: 1. Set Polarity to (–). 2. Continue testing per Procedure 12 for measuring IH (Reverse). Sidacs The sidac is a bidirectional voltage-triggered switch. Upon appli- cation of a voltage exceeding the sidac breakover voltage point, the sidac switches on through a negative resistance region (simi- lar to a diac) to a low on-state voltage. Conduction continues until current is interrupted or drops below minimum required holding current. To connect the sidac: 1. Connect MT1 to the Emitter Terminal (E). 2. Connect MT2 to the Collector Terminal (C). To begin testing, perform the following procedures. Procedure 1: (+) VDRM, (+)IDRM, (-)VDRM, (-)IDRM Note: The (+) and (-) symbols are used to designate the polarity of MT2 with reference to MT1. To measure the (+)VDRM, (+)IDRM, (-)VDRM, and (-)IDRM parameter: 1. Set Variable Collector Supply Voltage Range to 1500 Max Peak Volts. 2. Set Horizontal knob to 50 V/DIV. 3. Set Mode to Leakage. 4. Set Polarity to (+). 5. Set Power Dissipation to 2.2 W. (2W on 370) 6. Set Terminal Selector to Emitter Grounded-Open Base. 7. Set Vertical knob to 50 µA/DIV. (Due to leakage mode, the CRT readout will show 50 nA.) Procedure 2: (+)VDRM and (+)IDRM To measure the (+)VDRM and (+)IDRM parameter: 1. Set Left-Right Terminal Jack Selector to correspond with the location of the test fixture. 2. Increase Variable Collector Supply Voltage to the rated VDRM of the device and observe the dot on the CRT. Read across horizontally from the dot to the vertical current scale. This measured value is the leakage current. (Figure AN1006.22) Figure AN1006.22 IDRM = 50 nA at VDRM = 90 V 5 mA 5 V PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV IH 50 nA 50 V PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV VDRM IDRM |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |