| Motore di ricerca datesheet componenti elettronici |
|
TRM-915-R250 Scheda tecnica(PDF) 10 Page - Linx Technologies |
|
|
|||||||||||||||||||||||||||||
TRM-915-R250 Scheda tecnica(HTML) 10 Page - Linx Technologies |
|
10 / 39 page ![]() – – – – 14 15 GUID Networking Mode GUID networking mode is the simplest mode and supports point-to-point and broadcast communications. Each module is programmed at the factory with a unique 4-byte ID number that cannot be changed. These bytes are found in the non-volatile read only MYGUID registers (regMYGUID[0-3]). GUID networking mode uses these IDs as addresses. The transmitting unit’s GUID is used as the source address and the intended receiver’s GUID is written into the destination address register (regDESTGUID[0-3]). All modules within range hear the transmission, but only the module with the ID that matches the destination address outputs the data on its UART. All others ignore the transmission. A broadcast message is created when the destination address is 0xFFFFFFFF. In this case, all modules within range output the data. It is not recommended to send broadcast messages when acknowledgements are enabled. Figure 11 lists some examples of how GUID networking works. Networking Modes The module has a very flexible addressing and networking scheme selected with the regNVNETWORKMODE and regNETWORKMODE registers. It can be changed during operation. The transmitting module addresses packets according to the network mode configuration. The receiving module processes all addressing types regardless of the network mode configuration. If the received message matches the addressing criteria, it is output on the UART. Otherwise it is discarded. There are three networking modes: GUID, User and Extended User. Each mode offers different communications schemes, but all use source and destination addressing. The source address is for the transmitting unit, the destination address is the intended receiver. Each mode uses different registers for the source and destination addresses. The module supports an automatic addressing mode that reads the Source Address from a received packet and uses it to fill the Destination Address register. This makes sure that a response is sent to the device that transmitted the original message. This also allows the host microcontroller to read out the address of the sending unit. The automatic addressing is enabled for the different networking modes with register regAUTADD and regNVAUTADD. 250 Series Transceiver GUID Network Mode Examples Sender Receiver Network Mode MyGUID Destination GUID MyGUID Response 0x04 (GUID) 0x00001000 0xFFFFFFFF 0x00002000 Data output by both modules. No RF ACK sent by either module. 0x00003000 0x14 (GUID + ACK) 0x00001000 0xFFFFFFFF 0x00002000 Data output by both modules. No ACK sent by either module. This configuration causes transmission problems. 0x00003000 0x14 (GUID + ACK) 0x00001000 0x00003000 0x00002000 Not processed – discarded. 0x00003000 Data output. RF ACK sent to 0x00001000 0x04 (GUID) 0x00001000 0x00002000 0x00002000 Data output. No RF ACK sent. 0x00003000 Not processed – discarded. Figure 11: 250 Series Transceiver GUID Network Mode Examples |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |