25 / 39 page ![]() – – – – 44 45 CSMA Enable - Address = 0x56; NV Address = 0x0B Carrier-Sense Multiple Access (CSMA) is a transmission protocol that listens to the channel before transmitting a message. If another module is already transmitting when a message is queued, the module waits before sending its payload. This helps to eliminate RF message corruption at the expense of additional latency. Setting the regCSMAMODE register to 0x01 enables CSMA and 0x00 disables CSMA. By default, CSMA is enabled. Figure 45 shows examples of the commands and Figure 46 shows the available values. Figure 45: 250 Series CSMA Enable Command and Response 250 Series CSMA Enable Register Settings V1 Mode 0x00 Disable CSMA 0x01 Enable CSMA Figure 46: 250 Series CSMA Enable Register Settings 250 Series CSMA Enable Read Command Read Response Header Size Escape Address ACK Address Value 0xFF 0x02 0xFE 0x56 0x0B 0x06 0x56 0x0B V1 Write Command Header Size Address Value 0xFF 0x02 0x56 0x0B V1 Show Version - Address = 0x0A Setting this register to 0x00 suppresses the start-up message, including firmware version, which is sent to the UART when the module is reset. A value of 0x01 causes the message to be output after reset. By default, the module start-up message is output. Figure 43 shows examples of the commands and Figure 44 shows the available values. Figure 43: 250 Series Show Version Command and Response Figure 44: 250 Series Show Version Register Settings 250 Series Show Version Register Settings V1 Meaning 0x00 Startup message is NOT output on reset or power-up. 0x01 Startup message is output on reset or power-up. This is a blocking call, and any incoming UART data is lost during the transmission of this message through the TXD line. All UART commands must be sent after this message has completed. 0x02 Startup message is displayed upon reset or power-up. This is a non-blocking call. Any incoming UART data is buffered, and incoming UART commands are processed. If a change of baud rate is commanded while the startup message is being output, the current byte finishes at the current baud rate, and subsequent bytes are transmitted at the new baud rate. 250 Series Show Version Read Command Read Response Header Size Escape Address ACK Address Value 0xFF 0x02 0xFE 0x0A 0x06 0x0A V1 Write Command Header Size Address Value 0xFF 0x02 0x0A V1 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |