| Motore di ricerca datesheet componenti elettronici |
|
ST25DV64KC Scheda tecnica(PDF) 15 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25DV64KC Scheda tecnica(HTML) 15 Page - STMicroelectronics |
|
15 / 203 page ![]() Table 5. Maximum user memory block and byte addresses and ENDAi value Device Last user memory block address seen by RF Last user memory byte address seen by I2C Maximum ENDAi value ST25DV04KC 007Fh 01FFh 0Fh ST25DV16KC 01FFh 07FFh 3Fh ST25DV64KC 07FFh 1FFFh FFh Table 6. Areas and limit calculation from ENDAi registers Area Seen from RF interface Seen from I2C interface Area 1 Block 0000h … Block (ENDA1*8)+7 Byte 0000h … Byte (ENDA1*32)+31 Area 2 Block (ENDA1+1)*8 … Block (ENDA2*8)+7 Byte (ENDA1+1)*32 … Byte (ENDA2*32)+31 Area 3 Block (ENDA2+1)*8 … Block (ENDA3*8)+7 Byte (ENDA2+1)*32 … Byte (ENDA3*32)+31 Area 4 Block (ENDA3+1)*8 … Last memory Block Byte (ENDA3+1)*32 … Last memory Byte Organization of user memory in areas have the following characteristics: • At least one area exists (Area1), starting at Block/Byte address 0000h and finishing at ENDA1, with ENDA1 = ENDA2 = ENDA3 = End of user memory (factory setting). • Two Areas could be defined by setting ENDA1 < ENDA2 = ENDA3 = End of user memory. • Three Areas may be defined by setting ENDA1 < ENDA2 < ENDA3 = End of user memory. • A maximum of four areas may be defined by setting ENDA1 < ENDA2 < ENDA3 < End of user memory. • Area 1 specificities – Start of Area1 is always Block/Byte address 0000h. – Area1 minimum size is 8 blocks (32 bytes) when ENDA1 = 00h. – Area1 is always readable. • The last area always finishes on the last user memory Block/Byte address (ENDA4 doesn't exist). • All areas are contiguous: end of Area(n) + one Block/Byte address is always start of Area(n+1). Area size programming RF user must first open the RF configuration security session to write ENDAi registers. I2C host must first open I2C security session to write ENDAi registers. When programming an ENDAi register, the following rule must be respected: • ENDAi-1 < ENDAi ≤ ENDAi+1 = End of memory. This means that prior to programming any ENDAi register, its successor (ENDAi+1) must first be programmed to the last Block/Byte of memory: • Successful ENDA3 programming condition: ENDA2 < ENDA3 ≤ End of user memory • Successful ENDA2 programming condition: ENDA1 < ENDA2 ≤ ENDA3 = End of user memory • Successful ENDA1 programming condition: ENDA1 ≤ ENDA2 = ENDA 3 = End of user memory ST25DV04KC ST25DV16KC ST25DV64KC User memory DS13519 - Rev 3 page 15/203 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |