Back Button MCT8317A Datasheet HTML 22Page - Texas Instruments MCT8317A Datasheet HTML 23Page - Texas Instruments MCT8317A Datasheet HTML 24Page - Texas Instruments MCT8317A Datasheet HTML 25Page - Texas Instruments MCT8317A Datasheet HTML 26Page - Texas Instruments MCT8317A Datasheet HTML 27Page - Texas Instruments MCT8317A Datasheet HTML 28Page - Texas Instruments MCT8317A Datasheet HTML 29Page - Texas Instruments MCT8317A Datasheet HTML 30Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 161 page
background image
0
ZERO_
DUTY_
THR
MIN_
DUTY
SPEED_REF /
POWER_REF/
TARGET_DUTY
MIN_DUTY x MAX_SPEED /
MIN_DUTY x MAX_POWER /
MIN_DUTY
DUTY_CMD
100%
MAX_SPEED /
MAX_POWER/
100%
ZERO_
DUTY_
THR +
ZERO_
DUTY_
HYST
Figure 8-13. Control Input Transfer Function
When speed/power loop is disabled (CLOSED_LOOP_MODE = 00b), DUTY_CMD sets the TARGET_DUTY in
% - TARGET_DUTY is 100% when DUTY_CMD is 100% and TARGET_DUTY is equal to MIN_DUTY when
DUTY_CMD is set to MIN_DUTY. TARGET_DUTY stays clamped at MIN DUTY for ZERO_DUTY_THR ≤
DUTY_CMD ≤ MIN_DUTY.
When speed loop is enabled (CLOSED_LOOP_MODE = 01b), DUTY_CMD sets the SPEED_REF
in Hz. MAX_SPEED sets the SPEED_REF at DUTY_CMD of 100%. MIN_DUTY sets the minimum
SPEED_REF (MIN_DUTY x MAX_SPEED). SPEED_REF stays clamped at (MIN_DUTY x MAX_SPEED) for
ZERO_DUTY_THR ≤ DUTY_CMD ≤ MIN_DUTY.
When power loop is enabled (CLOSED_LOOP_MODE = 10b), DUTY_CMD sets the POWER_REF
in W. MAX_POWER sets the POWER_REF at DUTY_CMD of 100%. MIN_DUTY sets the minimum
POWER_REF (MIN_DUTY x MAX_POWER). POWER_REF stays clamped at (MIN_DUTY x POWER_REF)
for ZERO_DUTY_THR ≤ DUTY_CMD ≤ MIN_DUTY.
ZERO_DUTY_THR sets the DUTY_CMD below which SPEED_REF / POWER_REF / TARGET_DUTY is set to
zero and motor is in stopped state. AVS, CL_ACC configure the transient characteristics of DUTY_OUT; the
steady state value of DUTY_OUT is directly configured in % through TARGET_DUTY (when speed/power loop is
disabled) or through SPEED_REF/POWER_REF (when speed/power loop is enabled).
8.3.7.5.1 Linear Reference Profile
Note
For all types of reference profiles, duty command < ZERO_DUTY_THR stops the motor irrespective of
the speed profile register settings.
MCT8317A
SLLSFQ2 – JANUARY 2023
www.ti.com
26
Submit Document Feedback
Copyright © 2023 Texas Instruments Incorporated
Product Folder Links: MCT8317A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com