45 / 62 page ![]() www.ti.com Conversion Controlled by Host (TSMode 3) t COORDINATE + OH1 f OSC ) tPRE)tSNS) OH DLY2 f OSC )N @ (B)2) @ f OSC f ADC )OHCONV @ 1 f OSC ) L PPRO f OSC (8) Programmed forHost- Controlled Mode (PSM=0) X Scan Mode Programmedfor: TurnOn X+and X Drivers - (1) Reading Y-Data Register TouchisDetected NOTE:(1)Optional.Ifnotturnedon,itwillbeturnedonbytheScanmode,oncedetected. Y Scan Mode Programmedfor: TurnOn Y+and Y Drivers - (1) Reading X-Data Register Detecting Touch WaitingforHosttoWriteInto ControlByte1D[6:3] PINTDAV Programmed: As , CFR2,D[15:14]=10 PENIRQ As , CFR2,D[15:14]=11or01 DAV As and , CFR2,D[15:14]=00 PENIRQ DAV TouchisDetected TouchisDetected Sample,Conversion, andPreprocessing forXCoordinate Detecting Touch Sample,Conversion, andPreprocessing forYCoordinate Detecting Touch WaitingforHostto WriteIntoControl Byte1D[6:3] WaitingforHosttoWriteInto ControlByte1D[6:3] t COORDINATE t COORDINATE TSC Not Addressed TSC Not Addressed TSC Not Addressed TSC Not Addressed TSC2004 SBAS408E – JUNE 2007 – REVISED MARCH 2008 In TSMode 3, the TSC2004 detects when the touch panel is touched and causes the internal Pen-Touch signal to be active, which lowers the PINTDAV output if it is programmed as PENIRQ. The host recognizes the interrupt request. Instead of starting a sequence in the TSC2004, which then reads each coordinate in turn, the host must now control all aspects of the conversion. Generally, upon receiving the interrupt request, the host turns on the X drivers. (NOTE: If drivers are not turned on, the device detects this condition and turns them on before the scan starts. This situation is why the event of Turn On Drivers is shown as optional in Figure 42 and Figure 43.) After waiting for the settling time, the host then addresses the TSC2004 again, this time requesting an X coordinate conversion. The process is then repeated for the Y and Z coordinates. The processes are outlined in Figure 42 and Figure 43. Figure 42 shows two consecutive scans on X and Y. Figure 43 shows a single Z scan. The time needed to convert any single coordinate X or Y under host control (not including the time needed to send the command over the I2C bus) is given by: Where: OHDLY2 = total overhead time for tPRE and tSNS = 6 internal clock cycles. Figure 42. Example of X and Y Coordinate Touch Screen Scan using TSMode 3 Copyright © 2007–2008, Texas Instruments Incorporated Submit Documentation Feedback 45 Product Folder Link(s): TSC2004 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |