| Motore di ricerca datesheet componenti elettronici |
|
DS1821 Scheda tecnica(PDF) 6 Page - Dallas Semiconductor |
|
|
|||||||||||||||||||||||||||||
DS1821 Scheda tecnica(HTML) 6 Page - Dallas Semiconductor |
|
6 / 16 page ![]() DS1821 6 of 16 PROGRAMMING COMMAND FUNCTIONS The command set for the DS1821 as shown in Table 2 is as follows: Read Temperature [AAh] This command reads the contents of the register which contains the last temperature conversion result. Write TH [01h] This command writes to the TH (HIGH TEMPERATURE) register. After issuing this command, the user writes 8 bits of data to the TH register. Write TL [02h] This command writes to the TL (LOW TEMPERATURE) register. After issuing this command, the user writes 8 bits of data to the TL register. Read TH [A1h] This command reads the value of the TH (HIGH TEMPERATURE) register. After issuing this command, the user reads the 8 bits of data present in the TH register. Read TL [A2h] This command reads the value of the TL (LOW TEMPERATURE) register. After issuing this command, the user reads the 8 bits of data present in the TL register. Write Status [0Ch] This command writes to the status register. This would be used for clearing the values of the THF and TLF flags, and setting the T/ R , POL and 1SHOT bits. After issuing this command, the user writes the 8- bit data into the register. Read Status [ACh] This command reads the value in the status register. After issuing this command, the user reads the 8 bits present in the status register. Start Convert T [EEh] This command begins a temperature conversion. No further data is required. In One-Shot mode, the temperature conversion will be performed and then the DS1821 will remain idle. In continuous mode, this command will initiate continuous conversions. Stop Convert T [22h] This command stops temperature conversion. No further data is required. This command may be used to halt a DS1821 in continuous conversion mode. After issuing this command, the current temperature measurement will be completed, and then the DS1821 will remain idle until a Start Convert T is issued to resume continuous operation. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |