Back Button HTG13J0 Datasheet HTML 20Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 21Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 22Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 23Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 24Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 25Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 26Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 27Page - Holtek Semiconductor Inc HTG13J0 Datasheet HTML 28Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 30 page
background image
HT13J0
24
May19,1999
MOVR4,XH
MoveimmediatedatatoR4
MachineCode
010001100000dddd
Description
The4-bitdataspecifiedbycodeareloadedtotheworkingregisterR4.
Operation
R4
¬ XH
MOVRn,A
Moveaccumulatortoregister
MachineCode
0010nnn0
Description
Dataintheaccumulatorismovedtotheworkingregister"Rn".
Operation
Rn
¬ ACC;Rn=R0,R1,R2,R3,R4,forn=0,1,2,3,4
MOVTMRH,A
Moveaccumulatortotimer
MachineCode
00111101
Description
The contents of the accumulator is loaded to the high nibble of timer
counter.
Operation
TIMER(highnibble)
¬ ACC
MOVTMRL,A
Moveaccumulatortotimer
MachineCode
00111100
Description
The contents of the accumulator is loaded to the low nibble of timer coun-
ter.
Operation
TIMER(lownibble)
¬ ACC
MOV[R1R0],A
Moveaccumulatortodatamemory
MachineCode
00000101
Description
Data in the accumulator is moved to the data memory specified by the
registerpair"R1,R0".
Operation
M(R1,R0)
¬ ACC
MOV[R3R2],A
Moveaccumulatortodatamemory
MachineCode
00000111
Description
Data in the accumulator is moved to the data memory specified by the
registerpair"R3,R2".
Operation
M(R3,R2)
¬ ACC
NOP
Nooperation
MachineCode
00111110
Description
Donothing,butoneinstructioncycleisdelayed.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com