159 / 223 page ![]() Application Notes AN1006 ©2002 Teccor Electronics AN1006 - 7 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 8. Set Power Dissipation to 2.2 W. (2W on 370) For sensitive SCRs, set at 0.5 W. (0.4 W on 370) 9. Set Horizontal knob to 2 V/DIV. 10. Set Vertical knob to 50 mA/DIV. 11. Increase Variable Collector Supply Voltage until voltage reaches 12 V on CRT. 12. After 12 V setting is completed, change Horizontal knob to Step Generator. Procedure 7: IGT To measure the IGT parameter: 1. Set Step/Offset Amplitude to 20% of maximum rated IGT. Note: RGK should be removed when testing IGT. 2. Set Left-Right Terminal Jack Selector to correspond with location of the test fixture. 3. Gradually increase Offset Multiplier until device reaches the conduction point. (Figure AN1006.9) Measure IGT by fol- lowing horizontal axis to the point where the vertical line crosses axis. This measured value is IGT. (On 370, IGT will be numerically displayed on screen under offset value.) Figure AN1006.9 IGT = 25 µA Procedure 8: VGT To measure the VGT parameter: 1. Set Offset Multiplier to 0 (zero). (Press Aid and Oppose at the same time on 370.) 2. Set Step Offset Amplitude to 20% rated VGT. 3. Set Left-Right Terminal Jack Selector to correspond with location of test fixture. 4. Gradually increase Offset Multiplier until device reaches the conduction point. (Figure AN1006.10) Measure VGT by following horizontal axis to the point where the vertical line crosses axis. This measured value is VGT. (On 370, VGT will be numerically displayed on screen, under offset value.) Procedure 9: GT will be numerically displayed on screen under offset value.) Figure AN1006.10 VGT = 580 mV Triacs Triacs are full-wave bidirectional AC switches turned on when current is supplied to the gate terminal of the device. If gate con- trol in all four quadrants is required, then a sensitive gate triac is needed, whereas a standard triac can be used if gate control is only required in Quadrants I through III. To connect the triac: 1. Connect the Gate to the Base Terminal (B). 2. Connect MT1 to the Emitter Terminal (E). 3. Connect MT2 to the Collector Terminal (C). To begin testing, perform the following procedures. Procedure 1: (+)VDRM, (+)IDRM, (-)VDRM, (-)IDRM Note: The (+) and (-) symbols are used to designate the polarity MT2 with reference to MT1. To measure the (+)VDRM, (+)IDRM, (-)VDRM, and (-)IDRM parameter: 1. Set Variable Collector Supply Voltage Range to appropri- ate Max Peak Volts for device under test. (Value selected should be equal to the device’s VDRM rating.) WARNING: Do NOT exceed VDRM/VRRM rating of SCRs, tri- acs, or Quadracs. These devices can be damaged. 2. Set Horizontal knob to sufficient scale to allow viewing of trace at the required voltage level. (The 100 V/DIV scale should be used for testing devices having a VDRM rating of 600 V or greater; the 50 V/DIV scale for testing parts rated from 30 V to 500 V, and so on.) 3. Set Mode to Leakage. 4. Set Polarity to (+). 5. Set Power Dissipation to 0.5 W. (0.4 W on 370) 6. Set Terminal Selector to Emitter Grounded-Open Base. 7. Set Vertical knob to ten times the maximum leakage current (IDRM) specified for the device. Note: The CRT screen readout should show 1% of the maxi- mum leakage current. The vertical scale is divided by 1,000 when leakage mode is used. 50 mA PER V E R T DIV PER H O R I Z DIV PER S T E P IGT ()k DIV 9m PER DIV 10 A 5 K 50 mA PER V E R T DIV PER H O R I Z DIV PER S T E P VGT 200 mV 250m ()k DIV 9m PER DIV |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |