| Motore di ricerca datesheet componenti elettronici |
|
AC08FSM Scheda tecnica(PDF) 161 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
AC08FSM Scheda tecnica(HTML) 161 Page - Teccor Electronics |
|
161 / 223 page ![]() Application Notes AN1006 ©2002 Teccor Electronics AN1006 - 9 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 3. Set Max Peak Volts to 75 V. (80 V on 370) 4. Set Mode to DC. 5. Set Horizontal knob to Step Generator. 6. Set Vertical knob to approximately 10% of the maximum IH specified. Note: Due to large variation of holding current values, the scale may have to be adjusted to observe holding current. 7. Set Number of Steps to 1. 8. Set Step/Offset Polarity to non-inverted (button extended, on 577 button depressed). 9. Set Offset by depressing 0 (zero). (Press Aid and Oppose at same time on 370.) 10. Set Terminal Selector to Step Generator-Emitter Grounded. Procedure 8: IH(Forward) To measure the IH (Forward) parameter: 1. Set Polarity to (+). 2. Set Left-Right Terminal Jack Selector to correspond with location of test fixture. 3. Increase Variable Collector Supply Voltage to maximum position (100). 4. Set Step Family by depressing Single. This could possibly cause the dot on the CRT to disappear, depending on the vertical scale selected). 5. Decrease Variable Collector Supply Voltage to the point where the line on the CRT changes to a dot. The position of the beginning point of the line, just before the line becomes a dot, represents the holding current value. (Figure AN1006.13) Figure AN1006.13 IH (Forward) = 8.2 mA Procedure 9: IH(Reverse) To measure the IH (Reverse) parameter: 1. Set Polarity to (–). 2. Repeat Procedure 7 measuring IH(Reverse). (Read measure- ments from upper right corner of the screen.) Procedure 10: IGT To measure the IGT parameter: 1. Set Polarity to (+). 2. Set Number of Steps to 1. (Set number of steps to 0 (zero) on 370.) 3. Set Offset by depressing Aid. (On 577, also set Zero button to Offset. Button is extended.) 4. Set Offset Multiplier to 0 (zero). (Press Aid and Oppose at same time on 370.) 5. Set Terminal Selector to Step Generator-Emitter Grounded. 6. Set Mode to Norm. 7. Set Max Peak Volts to 15 V. (16 V on 370) 8. Set Power Dissipation to 10 W. 9. Set Step Family by depressing Single. 10. Set Horizontal knob to 2 V/DIV. 11. Set Vertical knob to 50 mA/DIV. 12. Set Step/Offset Polarity to non-inverted position (button extended, on 577 button depressed). 13. Set Variable Collector Supply Voltage until voltage reaches 12 V on CRT. 14. After 12 V setting is completed, change Horizontal knob to Step Generator. Procedure 11: IGT – Quadrant I [MT2 (+) Gate (+)] To measure the IGT – Quadrant I parameter: 1. Set Step/Offset Amplitude to approximately 10% of rated IGT. 2. Set Left-Right Terminal Jack Selector to correspond with location of test fixture. 3. Gradually increase Offset Multiplier until device reaches conduction point. (Figure AN1006.14) Measure IGT by follow- ing horizontal axis to the point where the vertical line passes through the axis. This measured value is IGT. (On 370, IGT is numerically displayed on screen under offset value.) Figure AN1006.14 IGT in Quadrant I = 18.8 mA 5 mA 100m PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV 50 mA IH 50 mA 10 PER V E R T DIV PER H O R I Z DIV PER S T E P ()k DIV 9m PER DIV 5 mA IGT |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |