157 / 223 page ![]() Application Notes AN1006 ©2002 Teccor Electronics AN1006 - 5 http://www.teccor.com Thyristor Product Catalog +1 972-580-7777 Figure AN1006.4 VFM = 1 V at IPK = 20 A SCRs SCRs are half-wave unidirectional rectifiers turned on when cur- rent is supplied to the gate terminal. If the current supplied to the gate is to be in the range of 12 µA and 500 µA, then a sensitive SCR is required; if the gate current is between 1 mA and 50 mA, then a non-sensitive SCR is required. To connect the rectifier: 1. Connect Anode to Collector Terminal (C). 2. Connect Cathode to Emitter Terminal (E). Note: When sensitive SCRs are being tested, a 1 k Ω resistor must be connected between the gate and the cathode, except when testing IGT. To begin testing, perform the following procedures. Procedure 1: VDRM, VRRM, IDRM, IRRM To measure the VDRM, VRRM, IDRM, and IRRM parameter: 1. Set Variable Collector Supply Voltage Range to appropri- ate Max Peak Volts for device under test. (Value selected should be equal to or greater than the device’s VDRM rating.) 2. Set Horizontal knob to sufficient scale to allow viewing of trace at the required voltage level. (The 100 V/DIV scale should be used for testing devices having a VDRM value of 600 V or greater; the 50 V/DIV scale for testing parts rated from 300 V to 500 V, and so on.) 3. Set Mode to Leakage. 4. Set Polarity to (+). 5. Set Power Dissipation to 0.5 W. (0.4 W on 370) 6. Set Terminal Selector to Emitter Grounded-Open Base. 7. Set Vertical knob to approximately ten times the maximum leakage current (IDRM, IRRM) specified for the device. (For sensitive SCRs, set to 50 µA.) Note: The CRT screen readout should show 1% of the maximum leakage current if the vertical scale is divided by 1,000 when leakage current mode is used. Procedure 2: VDRM, IDRM To measure the VDRM and IDRM parameter: 1. Set Left-Right Terminal Jack Selector to correspond with location of test fixture. 2. Set Variable Collector Supply Voltage to the rated VDRM of the device and observe the dot on CRT. Read across hori- zontally from the dot to the vertical current scale. This mea- sured value is the leakage current. (Figure AN1006.5) WARNING: Do NOT exceed VDRM/VRRM rating of SCRs, triacs, or Quadracs. These devices can be damaged. Figure AN1006.5 IDRM = 350 nA at VDRM = 600 V Procedure 3: VRRM, IRRM To measure the VRRM and IRRM parameter: 1. Set Polarity to (–). 2. Repeat Steps 1 and 2 (VDRM, IDRM) except substitute VRRM value for VDRM. (Figure AN1006.6) . Figure AN1006.6 IRRM = 340 nA at VRRM = 600 V Procedure 4: VTM To measure the VTM parameter: 1. Set Terminal Selector to Step Generator-Emitter Grounded. 2. Set Polarity to (+). 3. Set Step/Offset Amplitude to twice the maximum IGT rating of the device (to ensure the device turns on). For sensitive SCRs, set to 2mA. 4. Set Max Peak Volts to 15 V. (16 V on 370) 5. Set Offset by depressing 0 (zero). 500 mV PER V E R T DIV PER H O R I Z DIV PER S T E P IT VFM 2 A ()k DIV 9m PER DIV 100 nA 100 V PER V E R T DIV PER H O R I Z DIV PER S T E P VDRM IDRM ()k DIV 9m PER DIV 100 nA 100 V PER V E R T DIV PER H O R I Z DIV PER S T E P VRRM IRRM ()k DIV 9m PER DIV |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |