| Motore di ricerca datesheet componenti elettronici |
|
MB91301 Scheda tecnica(PDF) 25 Page - Fuji Electric |
|
|
|||||||||||||||||||||||||||||
MB91301 Scheda tecnica(HTML) 25 Page - Fuji Electric |
|
25 / 135 page ![]() MB91301 Series 25 • I-bus memory Do not set a stack area or vector table in I-bus memory. It may cause a hang during EIT processing (including RETI). Recovery from the hang requires a reset. Do not perform DMA transfer to I-bus memory. • Low-power consumption modes • To enter the standby mode, use the synchronous standby mode (set with the SYNCS bit as bit 8 in the TBCR, or time-base counter control register) and be sure to use the following sequence: (LDI #value_of_standby, R0) (LDI #_STCR, R12) STB R0, @R12 ; Write to standby control register (STCR) LDUB @R12, R0 ; Read STCR for synchronous standby LDUB @R12, R0 ; Read STCR again for dummy read NOP ; NOP x 5 for timing adjustment NOP NOP NOP NOP • If you use the monitor debugger, follow the precautions below: Do not set a breakpoint within the above array of instructions. Do not single-step the above array of instructions. • Prefetch When accessing a prefetch-enabled little endian area, use word access only (access in 32 bits). Byte or halfword access results in wrong data read. • MCLK and SYSCLK MCLK causes a stop in SLEEP/STOP mode while SYSCLK causes a stop only in STOP mode. Use either depending on each application. • Pull-up control When function pins listed in the AC specifications (such as external bus control pins) have pull-up control, enabling the pull-up resistor for a pin causes the actual pin load conditions to change. As all AC specifications for this device were measured under the condition of pull-up resistors disabled, the values are not guaranteed of AC specifications when pull-up resistors are enabled. Even if the pull-up resistor is set to enabled for a pin, if the HIZ bit in the standby control register (STCR) specifies setting output pins to high impedance during stop mode (HIZ = 1) , changing to stop mode (STOP = 1) causes the pull-up resistor to be disabled. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |