10 / 32 page ![]() THMC50 REMOTE/LOCAL TEMPERATURE MONITOR AND FAN CONTROLLER WITH SMBus INTERFACE SLIS090 – JULY 1999 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION functional description The THMC50 provides a remote thermal diode temperature sensor, an internal ambient temperature sensor, an analog output, and two voltage supervisors/reset generators. Temperatures read from the remote and internal sensors are converted into an 8-bit, 2s-complement digital word with a 1 °C LSB (least significant bit). The analog output is a 0-V to 2.5-V output from an 8-bit DAC that is used along with external circuitry to control the fan speed. The analog output is automatically set by the THMC50 to full on (0 ×FF), the FAN_OFF output floats (fan is on), and THERM is asserted low when either of two automatic trip points is exceeded for more than three monitoring cycle times. The FAN_SPD analog output will be reset to full off (0x00) whenever RST is asserted. The THMC50 provides a number of internal registers, as detailed in Table 1. These include: Register: Function: Configuration register Provides control and configuration, as well as initialization Interrupt status register Provides status of each limit or interrupt event Interrupt status register mirror Mirror registers can be used by second agent needing to monitor the THMC50 status. Interrupt mask register Allows masking of individual interrupt sources, as well as separate masking for the hardware interrupt output Value RAM The monitoring results and limits for temperature are all contained in the value RAM. When the THMC50 is first started, it performs temperature conversions at a rate of 1Hz. Each measured temperature value is compared to values stored in the limit registers. When the measured value exceeds the programmed limit, the THMC50 sets a corresponding error bit in the interrupt status register. An open drain hardware interrupt line, INT, is available to generate an interrupt. INT is fully programmable with masking of each interrupt source, and with masking of the INT output. The temperature monitoring section also has an open drain input/output, THERM. This line is asserted low internally whenever a critical temperature limit is exceeded for at least three monitoring cycles. It can also be asserted low externally. Whenever THERM is asserted low, either internally or externally, the analog output automatically goes to full scale (0xFF) and the FAN_OFF output floats (fan is on) in order to command the fan to full speed. SMBus interface When using the SMBus interface, a write always consists of the THMC50 SMBus interface address byte, followed by the internal address register byte, then the data byte (see Figure 2). There are two cases for a read: 1. If the internal address register is known to be at the desired address, simply read the THMC50 with the SMBus interface address byte, followed by the data byte read from the THMC50 (see Figure 5). 2. If the internal address register value is unknown, write to the THMC50 with the SMBus interface address byte, followed by the internal address register byte (see Figure 4). Next, restart the serial communication with a read consisting of the SMBus interface address byte, followed by the data byte read from the THMC50. The default power-on SMBus address for the THMC50 is 01011XX binary, where XX reflects the state defined by the add terminal. This allows up to three THMC50 devices to be used on a single system. Table 1 shows how the state of the add terminal is used to define the THMC50 SMBus slave address. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |