| Motore di ricerca datesheet componenti elettronici |
|
THMC50SSOPDBQ Scheda tecnica(PDF) 19 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
THMC50SSOPDBQ Scheda tecnica(HTML) 19 Page - Texas Instruments |
|
19 / 32 page ![]() THMC50 REMOTE/LOCAL TEMPERATURE MONITOR AND FAN CONTROLLER WITH SMBus INTERFACE SLIS090 – JULY 1999 19 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION temperature interrupt operation (continued) 100 °C High Low Temp ACPI control methods clear event ACPI control methods clear event ACPI control methods clear event † † † † † † 90 °C 80 °C 70 °C 60 °C 50 °C 40 °C † ACPI control methods adjust temperature limit values. INT Figure 15. Examples of Temperature Interrupt Events THERM operation The THERM output is used for fault tolerant fan control. It is asserted by the THMC50 whenever the remote thermal diode temperature or ambient temperature exceeds the appropriate automatic trip point for three consecutive acquisitions (see Figure 16). The remote and local thermal diode trip point values are contained in the programmable remote/local temperature automatic trip point registers (if bit 3 in the configuration register is set) or the default remote/local temperature automatic trip point (if bit 3 in the configuration register is cleared). The default trip points are hardware-set trip points that can be read from the value RAM. Programmable trip points provide for increased flexibility in the ability to tailor the thermal characteristics of the system. The programmable values can be written to, and then locked down, by writing a 1 to the write once bit located in the configuration register. THERM is asserted after three consecutive acquisitions of a remote or an internal temperature that exceeds the appropriate automatic trip points (based upon bit 3 of the configuration register). When THERM is asserted by the THMC50, it remains active (with FAN_SPD = 0xFF and FAN_OFF = FLOATING) until both the local and remote temperatures fall 5 °C below the appropriate automatic trip point values (based upon bit 3 of the configuration register) for three consecutive temperature acquisitions. Once THERM has been cleared, the FAN_SPD output returns to its previously programmed value and FAN_OFF returns to its previously programmed state. Note that when FAN_SPD goes to full scale (0xFF) during a THERM event, the value in the analog output register (0x19) reflects the previously programmed value and not 0xFF, unless 0xFF was the previously programmed value. When THERM is asserted internally, it causes INT to be unconditionally asserted. An external device that pulls THERM low causes the fan control to be turned to full on and corresponding status bits to be set. In addition, whenever THERM is active, the FAN_OFF bit in the configuration register is unconditionally set. Note that an INT generated by an external device pulling THERM low is maskable, but an INT generated by an internally generated THERM condition is not maskable. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |