| Motore di ricerca datesheet componenti elettronici |
|
D10DPFPG Scheda tecnica(PDF) 5 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
D10DPFPG Scheda tecnica(HTML) 5 Page - Banner Engineering Corp. |
|
5 / 16 page ![]() 3. TEACH the Output OFF condition. Method Action Result Push Button a. Present the Output OFF condition. b. Click the Static button. TEACH conditions accepted • Display flashes “PASS,” followed by a number (denoting contrast); see Figure 3 on page 4. • Sensor returns to RUN mode with new settings • Arrow icon turns green TEACH conditions not accepted • Display flashes “FAIL” and returns to “1St” • Arrow icon remains red • After 60 seconds, sensor returns to RUN mode (Arrow icon turns green) without changing settings Remote Input a. Present the Output OFF condition. b. Single-pulse the remote line. T Dynamic TEACH and Adaptive Thresholds Sensor positions threshold midway between taught conditions Darkest (no signal) Most Light (saturated signal) Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 4. Dynamic TEACH (Light Operate shown) Contrast Values 500+ Excellent: Very stable operation. 100-500 Good: Minor sensing variables will not affect sensing reliability. 32-99 Low: Minor sensing variables may affect sensing reliability. 0-31 Marginal: Consider an alternate sensing scheme. Figure 5. Dynamic Contrast Values • TEACH on-the-fly • Sets a single threshold • Threshold position is adjustable using the “+” and “-” buttons (see Manual Adjust on page 10) Dynamic TEACH is used to program sensitivity during actual machine run conditions. During Dynamic TEACH, the sensor takes multiple samples of the light and dark conditions and automatically sets the sensitivity at the optimum level. Dynamic TEACH activates the sensor’s adaptive threshold system, which continuously tracks minimum and maximum signal levels, and automatically maintains centering of the switch point between the light and dark conditions. The adaptive threshold system remains in effect during RUN mode to automatically adjust for changes in the light or the dark conditions. When Dynamic TEACH mode is used to program sensitivity, the output ON state (light or dark operate) will remain as it was last programmed. To change to either light or dark operate, use the SETUP mode (see Sensor Setup on page 10). Dynamic TEACH and Manual Adjust Sensitivity may be adjusted at any time when the sensor is in RUN mode by clicking the “+” and “-” buttons. However, when a manual adjustment is made, the adaptive threshold system is disabled (cancelled). 1. Access the Dynamic TEACH Mode. Method Action Result Push Button10 Press and hold the Dynamic (+) button. • Display flashes “dYn” • Arrow icon turns red Remote Input11 Hold the remote line low (to ground). 10 0.04 seconds ≤ "Click" ≤ 0.8 seconds 11 0.04 seconds ≤ T ≤ 0.8 seconds D10 Expert™– Dual Discrete Outputs P/N 64154 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 5 |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |