| Motore di ricerca datesheet componenti elettronici |
|
D10DPFPG Scheda tecnica(PDF) 14 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
D10DPFPG Scheda tecnica(HTML) 14 Page - Banner Engineering Corp. |
|
14 / 16 page ![]() Self-Diagnostic Error Modes In the unlikely event that the setup parameters are lost or become corrupt, the display will continuously scroll: “USEr PSF Error.” Reteach the sensor to recover. If the problem persists, contact your Banner representative for further information. Gate Input The pink wire is configured as a gate input. When this wire is pulled low (for example, to the sensor ground; 0–0.5 V dc), it inhibits the outputs from switching, while all other sensor functions continue to be enabled. This feature is useful for controlling when the outputs are allowed to change states. Gate input function response time is 1 millisecond. Specifications Required Fiber-Optic Cable Banner P-Series plastic fibers Sensing Beam Visible red, 680 nm or Visible green, 525 nm , depending on model Supply Voltage and Current 12 to 24V dc (10% maximum ripple) at less than 65 mA, exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration 2 NPN or 2 PNP, depending on model Output Rating 150 mA maximum load OFF-state leakage current: < 10 μA at 24 V dc ON-state saturation voltage: NPN < 1.5 V at 150 mA load PNP < 2.5 V at 150 mA load Output Protection Circuitry Protected against false pulse on power-up and continuous short-circuit Output Response Time Programmable, 50 microseconds, 200 microseconds, 1 millisecond, 2.5 milliseconds NOTE: < 1 second delay on power-up; outputs do not conduct during this time. Adjustments Push-button or remote programming of response time, OFF-delay, light/dark operate, and display Indicators Four-digit digital display plus LED indicators for active channel, push- button lockout, OFF-delay and light/dark operate selection; 2 yellow output indicators Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Environmental Rating NEMA 1, IEC IP50 Connections PVC-jacketed 2 m or 9 m (6.5' or 30') 6-wire integral cable or integral 6-pin Pico-style quick-disconnect Operating Conditions Temperature: −20 °C to +55 °C (−4 °F to +131°F) Storage Temperature: −20 °C to +80 °C (−4 °F to +176 °F) 90% at +50 °C maximum relative humidity (non-condensing) Number of Devices, Stacked Ambient Temperature Rating Load Specification 3 55 °C 150 mA 7 50 °C 50 mA 10 45 °C 50 mA Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Certifications D10 Expert™– Dual Discrete Outputs 14 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 64154 Rev. G |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |