6 / 16 page ![]() 2. TEACH the Sensing Conditions. Method Action Result Push Button Present the Output ON/OFF conditions while continuing to hold the Dynamic button. Remote Input Present the Output ON/OFF conditions while continuing to hold the remote line low (to ground). 3. Return to RUN Mode. Method Action Result Push Button Release the Dynamic button. TEACH conditions accepted • Display flashes “PASS,” followed by a number (denoting contrast); see Figure 5 on page 5 • Sensor returns to RUN mode with new settings • Arrow icon turns green TEACH conditions not accepted • Display flashes “FAIL” • Arrow icon remains red • Sensor returns to RUN mode (Arrow icon turns green) without changing settings Remote Input Release the remote line/switch. Single-Point Window Set • Sets a single ON condition that extends 200 counts above and below the taught condition (including ±100 counts hysteresis) • All other conditions (lighter or darker) result in OFF output • Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (see Manual Adjust on page 10) Window Set is most useful when a product may not always appear in the same place, or when other signals may appear. Window Set designates a sensing window, with the Output ON condition inside the window, and the Output OFF conditions outside the window. The sensor accepts a single sensing condition, and adds switching thresholds and hysteresis above and below that condition to create a sensing window. Output ON and OFF conditions can be reversed by changing Light/Dark Operate status in Setup mode. Window Set and Manual Adjust Using Manual Adjust with Window Set expands or contracts the size of the window. Sensor positions window thresholds ± 100 counts from the presented condition Darkest (no signal) Most Light (saturated signal) Taught Condition 200 counts Hysteresis 100 counts Hysteresis 100 counts Output OFF Output OFF Output ON Sensing window size adjusted by Manual Adjust Figure 6. Single-Point Window SET and Hysteresis (Light Operate shown) 1. Access the SET Mode. Method Action Result Push Button Press and hold the Static (-) button > 2 seconds. • Display flashes “1St” • Arrow icon turns red D10 Expert™– Dual Discrete Outputs 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 64154 Rev. G |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |