59 / 203 page ![]() Table 70. Security session type Security session Open by presenting Right granted when security session is open, and until it is closed RF user RF password 1, 2 or 3 (1) (RF_PWD_1, RF_PWD_2, RF_PWD_3) RF user access to protected user memory as defined in RFAiSS registers RF user write access to RF password 1, 2 or 3(2) RF configuration RF password 0 (RF_PWD_0) RF user write access to configuration static registers RF user write access to RF password 0 I2C I2C password (I2C_PWD) I2C host access to protected user memory as defined in I2CSS register I2C host write access to configuration static registers I2C host write access to I2C password 1. Password number must be the same as the one selected for protection. 2. Write access to the password number corresponding to the password number presented. All passwords are 64-bit long, and default factory passwords value is 0000000000000000h. The ST25DVxxKC passwords management is organized around RF and I2C dedicated set of commands to access the dedicated registers in system configuration area where password values are stored. The dedicated password commands in RF mode are: • Write Password command (code B1h): see Section 7.6.36 Present Password. • Present Password command (code B3h): see Section 7.6.36 Present Password. RF user possible actions for security sessions are: • Open RF user security session: Present Password command, with password number 1, 2 or 3 and the valid corresponding password • Write RF password: Present Password command, with password number (0, 1, 2 or 3) and the current valid corresponding password. Then Write Password command, with same password number (0, 1, 2 or 3) and the new corresponding password. • Close RF user security session: Present Password command, with a different password number than the one used to open session or any wrong password. Or remove tag from RF field (POR). Presenting a password with an invalid password number doesn't close the session. • Open RF configuration security session: Present Password command, with password number 0 and the valid password 0. • Close RF configuration security session: Present Password command, with a password number different than 0, or password number 0 and wrong password 0. Or remove tag from RF field (POR). Presenting a password with an invalid password number doesn't close the session. Opening any new RF security session (user or configuration) automatically close the previously open one (even if it fails). There is no interaction between I2C and RF security sessions. Both are independent, and can run in parallel. Caution: If ST25DVxxKC is powered through VCC, removing VCC during an RF command can abort the command. As a consequence, before writing a new password, RF user should check if VCC is ON, by reading EH_CTRL_Dyn register bit 3 (VCC_ON), and eventually ask host to maintain or to shut down VCC, before issuing the Write Password command in order to avoid password corruption. To make the application more robust, it is recommended to use addressed or selected mode during write password operations to get the traceability of which tags/UID have been programmed. ST25DV04KC ST25DV16KC ST25DV64KC Data protection DS13519 - Rev 3 page 59/203 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |