| Motore di ricerca datesheet componenti elettronici |
|
CC1010-RTR1 Scheda tecnica(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC1010-RTR1 Scheda tecnica(HTML) 34 Page - Texas Instruments |
|
34 / 152 page ![]() CC1010 SWRS047 Page 34 of 152 15.9 Power and Clock Modes Several power modes are defined to save power when running CC1010. The modes are described below. See also Table 15. 15.9.1 Active Mode In active mode the 8051 is running normally, executing instructions from the Flash program memory. The clock used in this mode could either be the main crystal oscillator, or it could be the 32 kHz oscillator. The current consumption depends on the actual frequency used. 15.9.2 Idle Mode After completing the instruction that sets the PCON.IDLE bit, Idle Mode is entered. In Idle Mode, the 8051 processing is stopped and internal registers maintain their current data, but all peripherals are still running. There are 3 ways to exit Idle Mode: • Activate any enabled interrupt. This clears the IDLE bit, terminating Idle Mode, and executes the ISR associated with the received interrupt. The RETI instruction at the end of the ISR causes the 8051 to return to the instruction following the one that enabled Idle Mode. • Activate any reset condition. All registers are then reset, and program execution will resume from address 0x0000 when the reset condition is cleared. • Turn the power off and on. The Power On Reset module should then be enabled, or an external reset signal should be applied during power up. 15.9.3 Power-Down Mode After completing the instruction that sets the PCON.STOP bit, the controller core and the peripherals are stopped. In Power- Down Mode, the clock trees of the 8051 and peripherals are disabled. Only the ADC clock tree is running. This enables the ADC to generate reset as will be described in the ADC section. Note that the PCON.STOP bit does not affect the clock oscillators; these will still be running if they are switched on when entering Power-Down Mode. To ensure minimum power-consumption, the ADC should be switched off and Power-down mode should be entered by switching off the oscillators instead of using the PCON.STOP bit. There are 2 ways to exit Power Down Mode: • Activate any reset condition. All registers are then reset, and program execution will resume when the reset condition is cleared. Program execution will then resume from address 0x0000. • Turn the power off and on. The Power On Reset module should then be enabled, or an external reset signal should be applied during power up. More information about minimising the power consumption of the CC1010 can be found in Application Note AN017 Low Power Systems Using The CC1010. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |