| Motore di ricerca datesheet componenti elettronici |
|
E39-R1 Scheda tecnica(PDF) 66 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Scheda tecnica(HTML) 66 Page - Omron Electronics LLC |
|
66 / 100 page ![]() Fiber Amplifiers, Communications Unit and Accessories E3NX-FA Fiber Amplifiers, Communications Unit and Accessories E3NX-FA 66 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 67 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 66 67 *2. At Power Supply Voltage of 10 to 30 VDC. *1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table. PLC operation via Communications Unit enables reading detected values and changing settings. *3. The following details apply to the input. *3-1. Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected. *4. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. *5. When connected to an OMRON NJ-series Controller. *6. The bank is not reset by the user reset function or saved by the user save function. Inputs / Outputs 2 outputs 1 output 2 outputs 1 output Output ― *1 ― ― ― ― ― ― ― 1 input 1 input ― External input Light source (wavelength) Red, 4-element LED (625 nm) 10 to 30 VDC , including 10% ripple (p-p) Power supply voltage Power consumption * 2 At Power Supply Voltege of 24 VDC. Standard Models: Normal mode : 840 mW max. (Current consumption at 35 mA max.) Eco function ON : 650 mW max. (Current consumption at 27 mA max.) Eco function LO : 750 mW max. (Current consumption at 31 mA max.) Advanced Models or Model for Sensor Communications Unit: Normal mode : 920 mW max. (Current consumption at 38 mA max.) Eco function ON : 680 mW max. (Current consumption at 28 mA max.) Eco function LO : 800 mW max. (Current consumption at 33 mA max.) Control output Load power supply voltage: 30 VDC max., open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. ― ― External input Refer to *3. Refer to *3. ― ― Indicators 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green) OUT Selection Indicator (orange)(only on models with 2 outputs) Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection Power supply reverse polarity protection and output short-circuit protection Supplied from the connector through the Sensor Communications Unit Protection circuits Response time Super-high-speed mode (SHS) * 4 Operate or reset for model with 1 output: 30 µs, with 2 outputs: 32 µs High-speed mode (HS) Operate or reset: 250 μs Standard mode (Stnd) Operate or reset: 1 ms Giga-power mode (GIGA) Operate or reset: 16 ms Sensitivity adjustment Smart tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (−99% to 99%)) or manual adjustment Mutual interference prevention Super-high-speed mode (SHS) * 4 Maximum connectable Units Possible for up to 0 units 30 units High-speed mode (HS) Possible for up to 10 units Standard mode (Stnd) Possible for up to 10 units Giga-power mode (GIGA) Possible for up to 10 units Functions Auto power control (APC) Always ON Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer. 1ms to 9999ms Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings * 6 Select from initial reset (factory defaults) or user reset (saved settings). Functions Eco mode *7 Select from OFF (digital displays lit), Eco ON (digital displays not lit) or Eco LO (digital displays dimmed) Bank switching Select from banks 1 to 4. Power tuning Select from ON or OFF. Output 1 Select from normal detection mode, or area detection mode. External input Select from input OFF, tuning, power tuning, emission OFF, zero reset, or bank switching. Select from input OFF, tuning, power tuning, emission OFF, zero reset, or bank switching. Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set to from 0 to 9,999. Ambient Illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. Ambient temperature range Ambient humidity range Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above Insulation resistance 20 MΩ min. (at 500 VDC) 2,000 m max. Dielectric strength 1,000 VAC at 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions Weight (packed state/unit only) Approx. 115 g/ Approx. 75 g Approx. 60 g/ Approx. 20 g Approx. 115 g/ Approx. 75 g Approx. 60 g/Approx. 20 g Approx. 65 g/Approx. 25 g Materials Case Cover Polycarbonate (PC) Polycarbonate (PC) Cable PVC Accessories Instruction Manual 150 m/s2 for 3 times each in X, Y, and Z directions Operating: Groups of 1 to 2 Amplifer Units: −25 to 55°C, Groups of 3 to 10 Amplifer Units: −25 to 50°C, Groups of 11 to 16 Amplifer Units: −25 to 45°C, Groups of 17 to 30 Amplifer Units: −25 to 40°C Storage: −30 to 70°C (with no icing or condensation) Operating: Groups of 1 to 2 Amplifer Units: 0 to 55°C, Groups of 3 to 10 Amplifer Units: 0 to 50°C, Groups of 11 to 16 Amplifer Units: 0 to 45°C, Groups of 17 to 30 Amplifer Units: 0 to 40°C Storage: −30 to 70°C (with no icing or condensation) Output 2 Select from normal detection mode, alarm output mode, or error output mode. Select from normal detection mode, alarm output mode, or error output mode. Contact input (relay or switch) Non-contact input (transistor) Input time*3-1 NPN type ON: Shorted to 0V (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. ON: 1.5V max. (Sourcing current: 1 mA max.). OFF: Vcc − 1.5 V to Vcc (Leakage current: 0.1 mA max.) ON : 9ms min. OFF : 20ms min. PNP type ON: Shorted to Vcc (Sinking current: 3 mA max.). OFF: Open or shorted to 0V. ON: Vcc − 1.5 V to Vcc (Sinking current: 3 mA max.). OFF: 1.5V max.(Leakage current: 0.1 mA max.) Standard Models: Normal mode : 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC) Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC) Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC) Advanced Models: Normal mode : 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC) Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC) Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC) Ratings and Specifications Type Standard Advanced Model for Sensor Communications Unit NPN output E3NX-FA7 E3NX-FA7TW E3NX-FA0 PNP output E3NX-FA9 E3NX-FA9TW Item Connecting method Wire-saving Connector 2 outputs 1 output ― 1 input E3NX-FA24 ― E3NX-FA54 E3NX-FA54TW M8 Connector Connector for Sensor Communications Unit E3NX-FA11 E3NX-FA41 Pre-wired E3NX-FA6 E3NX-FA8 Wire-saving Connector E3NX-FA21 E3NX-FA51 Pre-wired Select from normal detection mode, alarm output mode, or error output mode. Type Standard Advanced Model for Sensor Communications Unit NPN output E3NX-FA7 E3NX-FA7TW E3NX-FA0 PNP output E3NX-FA9 E3NX-FA9TW Item Connecting method Wire-saving Connector E3NX-FA24 ― E3NX-FA54 E3NX-FA54TW M8 Connector Connector for Sensor Communications Unit E3NX-FA11 E3NX-FA41 Pre-wired E3NX-FA6 E3NX-FA8 Wire-saving Connector E3NX-FA21 E3NX-FA51 Pre-wired With E3NW-ECT: 30 units *5 With E3NW-CRT: 16 units With E3NW-CCL: 16 units *7. Eco LO is supported for Amplifier Units manufactured in July 2014 or later. Pollution degree 3 (as per IEC 60947-1) Altitude Installation environment |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |