| Motore di ricerca datesheet componenti elettronici |
|
E39-R1 Scheda tecnica(PDF) 85 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Scheda tecnica(HTML) 85 Page - Omron Electronics LLC |
|
85 / 100 page ![]() Fiber Amplifiers, Communications Unit and Accessories E3X-HD Fiber Amplifiers, Communications Unit and Accessories E3X-HD 84 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 85 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 84 85 (1) Restore from the Incident Level Changed due to Dust and Dirt (3) Reset Settings • Power Tuning Hold and buttons for 1 second or longer without a workpiece in the area. 1. • Setting Reset (4) Save or Read Settings 1. (5) Prevent Mistake-operation Disables all button operations. [ ] is displayed when the button is pressed. 1. 2. 2. (2) Stable Detection Regardless of Incident Level Change due to Dust and Dirt Perform Smart Tuning. 1. Set the DPC function ON in SET mode. 2. Incident light level setting: The Step 1 incident level is adjusted to the power tuning level. Threshold setting: Not changed. If the value is low, it will be set to the minimum value in which an output is turned ON/OFF correctly. Initializes all the settings by returning them to the factory defaults. ,n hs t,ff ,ffd 500 stnd 500 6000 shs 125 ,ff 10 ---- MODE MODE MODE MODE Detection Function Response Time Light Level STND Standard mode SHS Super-high- speed mode* GIGA Giga mode HS High-speed mode 1 ms 50 μs 55 μs NPN PNP 16 ms 250 μs 12 times 0.25 times 1 time 1 (Standard) 2. Detection Function 3. DPC Function 4. Timer Function UP/DOWN 6. Percentage Tuning MODE One-shot Timer Keeps the output ON for a specified time regardless of the workpiece size variations. T T T T T T Off-delay Timer Holds the output ON for detection by PLC when the detection time is too short. On-delay Timer Delays the output ON after detection. Incident light No incident light ON OFF ON OFF L-ON D-ON Incident light No incident light ON OFF ON OFF L-ON D-ON Incident light No incident light ON OFF ON OFF L-ON D-ON UP/DOWN UP/DOWN UP/DOWN (Incident Light Level Example) dflt MODE UP/DOWN 1. Function Selection 5. Power Tuning Level Refer to “Convenient Setting Features” Smart Tuning is canceled if the detection mode is changed. * The communication and mutual interference prevention functions are disabled when the detection mode is set to super-high-speed mode. Setting Output Timer Changing the Target Incident Light Level (Power Tuning Level) Detecting Transparent or Small Workpiece B A Function Setting Description Function Setting Description Changing Light Level and Response Time Stable Detection Regardless of Incident Light Level Change Function Selection: [dflt] Function Selection: [,pt] 10 n-d 10 ,n-d 9999 p-lv ,ff per ,n per 10 9. Inverted Display 8. Digital Display MODE MODE MODE B A UP/DOWN UP/DOWN UP/DOWN Eco on Indicators (Green and Red digital displays) turn OFF in approx. 10 seconds after a key operation. Eco Lo Indicators (Green and Red digital displays) turn ON with low brightness in approx. 10 seconds after a key operation. Inverts the display upside down. The digital display shows the threshold value in red, and light incident level in green. 10. Eco Function Changing Digital Display in RUN Mode for Specific Purpose Mounting Amplifier in Inverted Direction Saving Power Consumption Setting Threshold using a Small or Fast Moving Workpiece Adjusting Optical Axis Checking the Channel No. in Group Mounting The ratio of the incident light level to the threshold is displayed in red digital figures. Holds the peak incident light level and displays it in green digital figures. Checking the Channel No. in Group Mounting. Displays the current level in the 80 to 120% range against the threshold value (100%). Threshold Light Level Ratio Peak Light Level Light Level Checking a Margin Against Threshold Threshold Setting for Intuitive Analog Display 120% 100% 80% 3000 3500 2000 Ch. No. Light Level 3000 150p Peak Light Level Bottom Light Level 8000 2000 std bar p-b per UP/DOWN 3 2 5 4 1 ,ff ,n v, ,ff rev 7. Differential Function MODE Differential Setting Response Time 1 2 3 4 5 250 μs 500 μs 1 ms 10 ms 100 ms Detecting Incident Light Level Change ,ff MODE • Key Lock Function Enable/Cancel (This procedure) (6) Reset Incident Light Level to "0" Changes the incident light level to "0". The threshold level is also shifted accordingly. • Zero Reset Function 3. 3. 2. 3. * Settings for other functions are returned to the detailed setting initial values. User-saved settings are retained. Smart Tuning is canceled. Saves the current settings. Reads out the saved settings. TUNE Refer to “Convenient Setting Features” Refer to “Smart Tuning” (a) (b) (c) (d) (a) (b) (c) (d) (e) (a) (b) (c) (d) (e) (a) (b) (c) (a) (b) (c) (d) (a) (b) (c) Perform the procedure with a workpiece in the area for reflective model setting. If the setting is made after position tuning, set both the through-beam model and reflective model with a workpiece. • Steps 1 and 2 can be reversed. • The DPC function will be disabled when a smart tuning error occurs, differential function with maximum sensitivity tuning is performed, or the first incident light level of the positioning tuning is low. • The incident light level is corrected to the power tuning level to maintain stable threshold and incident light levels. This provides stable detection regardless of the incident level changes caused by dirty sensor head, position error, or temperature changes. The zero reset function is canceled when either of the DPC function/differential function/Smart Tuning is performed. The incident light level in SET mode is a reference value. It may be changed when switched to detection mode. * Press either of UP/DOWN. Refer to “•Smart Tuning Error" for error displays. Refer to "Smart Tuning" Refer to "Power Tuning" Refer to “Detailed Settings”. ptun st Hold both for 1 sec. or longer Incident Light Level Threshold Level Stabilizes the displayed incident level by correcting internal incident level changes. Time Displayed incident Light Level The displayed incident level decreases and the DPC indicator starts blinking when incident level correction is not possible. rst Hold both for 3 sec. or longer 0 -1999 Hold both for 3 sec. or longer 2000 4000 Hold both for 3 sec. or longer The DPC indicator turns ON when the DPC function is effective. Convenient Setting Features Detailed Settings Setting is Completed Internal Incident Light Level Hold button and then hold button for 3 seconds or longer. L/D TUNE MODE UP/DOWN Select [rst ] in and press button. Item Initial Value 55 L-ON Threshold Value Control Output L/D Caution is required; the output is inverted if button is pressed first. Hold button and then hold button for 3 seconds or longer. L/D TUNE • User Save Function • User Reset Function L/D Caution is required; the output is inverted if button is pressed first. Select [save] in and press button. UP/DOWN MODE Select [save yes] in and press button. UP/DOWN MODE Select [rst] in and press button. UP/DOWN MODE Select [rst user] in and press button. UP/DOWN MODE Hold both for 3 sec. or longer Enable Cancel Hold button for 3 seconds or longer to enter SET mode. MODE SET mode provides the function settings described hereafter. The initial display shown after transition from one function to another represents the factory default. Changing Functions to Set in SET Mode [dflt]: Functions 1. to 5. can be set [,pt]: Functions 1. to 10. can be set. A A timer value can be set after pressing button when a timer menu (other display than “----”) is displayed. Use button to set the time. (1 to 9999 ms in 1 ms steps; the initial value: 10 ms) MODE UP/DOWN Use button to set the power tuning level. [100 to 9999 in 1 steps; the initial value: 9999] UP/DOWN Press button in [per ,n] menu, then use button to set the percentage tuning level. (−99% to 99% in 1% steps; the initial value: −10%) MODE UP/DOWN Detects if the absolute value of the incident light level change of the set response time is larger than the threshold value. The display shows the change of the incident light level of the set response time in red. Use button to specify the response time. When the differential function is enabled, the detection function setting is disabled. Smart tunings except power tuning are disabled. The adjustment range of power tuning is approx. 1 to 1/100 times. UP/DOWN Holds and displays the minimum value of the peak of the light incident and the maximum value of the bottom of the light interruption. • DPC Function (Use of the function with Through-beam model or Retro-reflective model is recommended) l, MODE UP/DOWN Select [rst] in and press button. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |