| Motore di ricerca datesheet componenti elettronici |
|
E39-R1 Scheda tecnica(PDF) 75 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E39-R1 Scheda tecnica(HTML) 75 Page - Omron Electronics LLC |
|
75 / 100 page ![]() Fiber Amplifiers, Communications Unit and Accessories E3NX-FA Fiber Amplifiers, Communications Unit and Accessories E3NX-FA 74 Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information 75 Installation Information Threaded Cylindrical Flat Sleeved Small Spot High Power Retro- reflective Limited- reflective Narrow view BGS Chemical- resistant, Oil-resistant Bending Heat- resistant Area Detection Liquid-level Vacuum FPD, Semi, Solar 74 75 Press button and then set the alarm output level with button. (0 to 100 P in 1-P increments, default: 50 P) ON-delay of 300 ms is applied. Error Output Mode: An output is made when a DPC error, EEPROM error, or Load short circuit detection error occurs. A A Function Setting Description Function Setting Description Press button with [husr] displayed and then set the hysteresis width with button. (0 to 9999) MODE UP/DOWN dflt 1. Function Selection A Function Setting Description MODE B UP/DOWN Inverts the display upside down. The digital display shows the threshold value in green, and light incident level in white. 14. Eco Function 15. Hysteresis width 16. Using the External Input to Write to EEPROM Mounting Ampli er in Inverted Direction Changing the Hysteresis Width Turning ON and OFF Writing to EEPROM ,ff ,n 13. Inverted Display MODE UP/DOWN V, ,ff reV 7. Power Tuning ON/OFF Setting MODE UP/DOWN ,n (5) Reset Incident Light Level to "0" Changes the incident light level to "0". The threshould level is also shifted accordingly. The lower limit of the threshold is −1,999. • Zero Reset Function 8. Percentage Tuning MODE UP/DOWN ,ff per ,n per Percentage Tuning: The thresholds are set as follows: High: Incident level from step 3 + Incident level from step 3 × Percentage tuning level Low: Incident level from step 3 − Incident level from step 3 × Percentage tuning level (6) Producing an Output When the Incident Level Is within an Area • Area Detection Mode Select [SET Mode] − [OUT1 Mode] − [Area Detection Mode]. Press button for at least 3 seconds to leave the SET mode. 1. Press button in [Detection Mode] to display OUT1 HIGH and OUT 1 LOW. “HIGH” and “LOW” will appear on the green digital display. 2. Press button for the high and low thresholds to execute smart tuning. 3. The maximum value and minimum value are displayed with Light-ON and Dark-ON respectively. (7) Monitoring the Incident Level for Sensing Objects Passing at High Speed • Change Finder Select [SET Mode]→[Digital Display] to set [d sp cfdr]. 1. Press button for 3 seconds or longer to leave the SET mode. 2. Send a workpiece past the Fiber Unit. 3. The maximum and minimum incident levels will be displayed for 0.5 seconds when the workpiece passes. 4. Passing time and Incident level Passing time and Incident level 0m 0 500m 63 (8) Determining If the Workpiece Can Be Detected • SolutionViewer Press button and button together for 3 seconds or longer to set [s,lu ,n]. To clear the setting, press button and button together for 3 seconds or longer to set [s,lu ,ff]. 1. Send a workpiece past the Fiber Unit. 2. Displaying the Passing Time and Difference in Incident Levels. 3. Press button and button together for 3 seconds or longer to leave SET mode. 4. Hi Lo ON OFF ON OFF Light-ON control output Dark-ON control output ,n hs t,ff ,ffd 500 stnd 500 4000 shs 125 ,ff 10 ---- MODE MODE MODE Detection Function ResponseTime Light Level STND Standard mode SHS Super-high- speed mode* GIGA Giga mode HS High-speed mode 1ms 30μs 16ms 250 μs 8 times 0.25 times 1 time 1(Standard) 2. Detection Function 3. DPC Function 4. Timer Function One-shot Timer Keeps the output ON for a specified time regardless of the workpiece size variations. ON/OFF-delay Timer Sets both ON-delay and OFF-delay timers. T T T T T T Off-delay Timer Holds the output ON for detection by PLC when the detection time is too short. On-delay Timer Delays the output ON after detection. Incident light No incident light ON OFF ON OFF L-ON D-ON Incident light No incident light ON OFF ON OFF L-ON D-ON Incident light Incident light No incident light ON OFF ON OFF L-ON UP/DOWN UP/DOWN (Incident Light Level Example) 5. Power Tuning Level Refer to “Convenient Setting Features” Smart Tuning is canceled if the detection mode is changed. * The communication and mutual interference prevention functions are disabled when the detection mode is set to super-high-speed mode. The response time for models with 2 outputs is 32 μs Setting Output Timer (Settings are displayed for both outputs for models with 2 outputs.) Changing Light Level and Response Time Stable Detection Regardless of Incident Light Level Change A Function Selection: [dflt] Function Selection: [,pt] 10 n-d 10 ,n-d 9999 p-lV 10 (a) (b) (c) (d) (a) ,n,f ---- (d) (b) (c) (a) (b) (c) (d) (a) (b) (c) (d) Tb Ta Tb No incident light ON OFF ON OFF Ta Setting ON or OFF Incident Level Adjustment when Tuning MODE UP/DOWN 1 6.BANK Switching Saving Settings in Each Bank BANK1 2 BANK2 3 BANK3 4 BANK4 Power Tuning OFF Setting Power Tuning ON Setting ptun ,ff ptun MODE UP/DOWN 32 hstd 32 ec\ husr Standard Setting User Setting MODE UP/DOWN ,n ,ff ON OFF 37 husr User Setting (Displayed for models with 2 outputs.) l,ff Iaser OFF MODE UP/DOWN 12.Digital Display MODE UP/DOWN Changing Digital Display in RUN Mode for Specic Purpose Checking a Margin Against Threshold std cfdr bar p-b per 9. Output 1 Mode MODE UP/DOWN 10.Output 2 Mode std ,ut area ,ut (a) (b) (c) (d) (e) ( f ) Checking the Light Level of Fast Moving Workpiece Thereshold Light level when the workpiece passes 9999 2000 Changing the Output Mode for Output 1 Changing the Output Mode for Output 2 Alarm Output Mode: Normal Detection Mode Area Detection Mode MODE UP/DOWN std ,ut alrm ,ut Normal Detection Mode Alarm Output Mode err ,ut Error Output Mode 11.External Input MODE UP/DOWN ,ff tune Input-OFF Tuning ptun Power Tuning Changing the Type of External Input First point Second point Less than 3 seconds Less than 3 seconds Less than 3 seconds ─ ─ 3secondsmin. Lessthan7seconds 7.0 s or longer 3 seconds or longer The closed-circuit input time for tuning is the same as the key input time. Enable/Cancel of Zero reset is the timing when input is turned off. 0rst Zero Reset BANK Switching OFF : 1, ON : 2 bank The settings thathave been changed by an external input with [,ff] will not be overwritten to prevent EEPROM from reaching its lifespan (1,000,000 writings). A D-ON L-ON D-ON B Enable Cancel 2000 9999 Before Passing 2000 1000 Immediately After Passing Hold button for 3 seconds or longer to enter SET mode. MODE SET mode provides the function settings described hereafter. The initial display shown after transition from one function to another represents the factory default. Changing Functions to Set in SET mode [dflt]: Functions 1. to 5. can be set [,pt]: Functions 1. to 16. can be set. A timer value can be set after pressing button when a timer menu (other display than “----”) is displayed. Use button to set the time. (1 to 9999 ms in 1 ms steps; the initial value: 10 ms) Use button to set the power tuning level. [100 to 9999 in 1 steps; the initial value: 9999] MODE UP/DOWN UP/DOWN Refer to “Convenient Setting Features” Changing the Target Incident Light Level (Power Tuning Level) Press button in [per ,n] menu, then use button to set the percentage tuning level. (−99% to 99% in 1% steps; the initial value: −10%) Refer to “Smart Tuning” Detecting Transparent or Small Workpiece MODE UP/DOWN 2-point Tuning Maximum Sensitivity Tuning Full Auto Tuning ─ 25 ms min. Power/ percentage tuning Position Tuning Enable Cancel Less than 3 seconds 3 seconds min. Zero reset The ratio of the incident light level to the threshold is displayed in white digital figures. Threshold Light Level Ratio 2000 150p (a) Setting Threshold using a Small or Fast Moving Workpiece Peak Light Level Bottom Light Level 8000 2000 (b) Holds and displays the minimum value of the peak of the light incident and the maximum value of the bottom of the light interruption. Setting for Intuitive Analog Display Threshold 120% 100% 80% (c) Displays the current level in the 80 to 120% range against the threshold value (100%). Adjusting Optical Axis Peak Light Level Light Level 3000 3500 (d) Holds the peak incident light level and displays it in green digital figures. Checking the Channel No. in Group Mounting Ch. No. Light Level 3000 Light level when the workpiece passes is displayed in white digital figures for 0.5 seconds. Checking the Channel No. in Group Mounting. ECo on Indicators (Green and White digital displays) turn OFF in approx. 10 seconds after a key operation. ECo Lo Indicators (Green and White digital displays) turn ON with low brightness in approx. 10 seconds after a key operation. Saving Power Consumption The hysteresis width is set to a default value. The hysteresis width is set so that the judgement output is stable near the threshold value. ( f ) (e) func ec\ l, ec\ sh\t The incident light level in SET mode is a reference value. It may be changed when switched to detection mode. Be sure to check the stability of outputs as there is a possibility of chattering. 0 2000 Hold both for 3 sec. or longer 6000 4000 Hold both for 3 sec. or longer Convenient Setting Features The OUT selection indicators shows items for output 1 or output 2 individually for each output. Detailed Settings Incident level threshold Passing time(ms or μs) func |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |