| Motore di ricerca datesheet componenti elettronici |
|
XC164CS Scheda tecnica(PDF) 58 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
XC164CS Scheda tecnica(HTML) 58 Page - Infineon Technologies AG |
|
58 / 71 page ![]() XC164 Derivatives Electrical Parameters Data Sheet 54 V2.1, 2003-06 Figure 14 Equivalent Circuitry for Analog Inputs 1) TUE is tested at VAREF = VDDP +0.1 V, VAGND = 0 V. It is guaranteed by design for all other voltages within the defined voltage range. If the analog reference supply voltage drops below 4.5 V (i.e. VAREF ≥ 4.0 V) or exceeds the power supply voltage by up to 0.2 V (i.e. VAREF = VDDP + 0.2 V) the maximum TUE is increased to ±3 LSB. This range is not 100% tested. The specified TUE is guaranteed only, if the absolute sum of input overload currents on Port 5 pins (see IOV specification) does not exceed 10 mA, and if VAREF and VAGND remain stable during the respective period of time. During the reset calibration sequence the maximum TUE may be ±4 LSB. 2) VAIN may exceed VAGND or VAREF up to the absolute maximum ratings. However, the conversion result in these cases will be X000H or X3FFH, respectively. 3) The limit values for fBC must not be exceeded when selecting the peripheral frequency and the ADCTC setting. 4) This parameter includes the sample time tS, the time for determining the digital result and the time to load the result register with the conversion result ( tSYS = 1 / fSYS). Values for the basic clock tBC depend on programming and can be taken from Table 14. When the post-calibration is switched off, the conversion time is reduced by 12 x tBC 5) The actual duration of the reset calibration depends on the noise on the reference signal. Conversions executed during the reset calibration increase the calibration time. The TUE for those conversions may be increased. 6) Not 100% tested, guaranteed by design and characterization. The given parameter values cover the complete operating range. Under relaxed operating conditions (temperature, supply voltage) reduced values can be used for calculations. At room temperature and nominal supply voltage the following typical values can be used: CAINTtyp = 12 pF, CAINStyp = 7 pF, RAINtyp = 1.5 kΩ, CAREFTtyp = 15 pF, CAREFStyp = 13 pF, RAREFtyp = 0.7 kΩ. m cs 0 4879_p.vsd R So urc e = V AIN C Ext R AIN , O n C AIN T - C AIN S C AIN S A /D C onverte r |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |