Back Button MB95F118MS Datasheet HTML 36Page - fujitsu semiconductor MB95F118MS Datasheet HTML 37Page - fujitsu semiconductor MB95F118MS Datasheet HTML 38Page - fujitsu semiconductor MB95F118MS Datasheet HTML 39Page - fujitsu semiconductor MB95F118MS Datasheet HTML 40Page - fujitsu semiconductor MB95F118MS Datasheet HTML 41Page - fujitsu semiconductor MB95F118MS Datasheet HTML 42Page - fujitsu semiconductor MB95F118MS Datasheet HTML 43Page - fujitsu semiconductor MB95F118MS Datasheet HTML 44Page - fujitsu semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 40 / 64 page
background image
MB95110M Series
40
131.072 kHz
16.384 kHz
2.45
5.5
32 kHz
10 MHz
4 MHz
3 MHz
5 MHz 6 MHz 7 MHz 8 MHz 9 MHz
3 MHz
4 MHz
5 MHz
6 MHz
7 MHz
8 MHz
9 MHz
10 MHz
7.5 MHz
16.25 MHz
0.5 MHz
5.5
2.45
3 MHz
10 MHz
3.5
• Main PLL operation frequency
Main clock frequency (FMP)
× 2.5
× 2
× 1
Source clock frequency (FSPL)
Main clock operating guarantee range
Sub PLL operating guarantee range
Sub clock mode, watch mode,
operating guarantee range
Main clock mode, main PLL mode,
operating guarantee range
PLL operating guarantee range
PLL operating guarantee range
Source clock frequency (FSP)
• Operating voltage − Operating frequency (TA = + 5 °C to + 35 °C)
• MB95FV100D-103
10 MHz
0.5MHz
2.7
3 MHz
5.5
131.072 kHz
16.384 kHz
2.7
32 kHz
5.5
3.5
16.25 MHz
Source clock frequency (FSPL)
Sub PLL, sub clock mode and
watch mode operation guarantee range
PLL operation guarantee range
Source clock frequency (FSP)
PLL operation guarantee range
Main clock operation guarantee range
Main clock mode and main PLL mode
operation guarantee range
• Operating voltage − Operating frequency (TA = − 40 °C to + 85 °C)
• MB95F114MS/F114NS/F116MS/F116NS/F118MS/F118NS/F114MW/F114NW/F116MW/F116NW/F118MW/F118 NW



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com