| Motore di ricerca datesheet componenti elettronici |
|
UCS1003-2 Scheda tecnica(PDF) 11 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1003-2 Scheda tecnica(HTML) 11 Page - Microchip Technology |
|
11 / 138 page ![]() 2014-2015 Microchip Technology Inc. DS20005346B-page 11 UCS1003-1/2/3 Short-Circuit Response Time tSHORT_LIM — 1.5 — µs Time from detection of short to current limit applied; no CBUS applied Short-Circuit Detection Time tSHORT — 6 — ms Time from detection of short to port power switch disconnect and ALERT# pin assertion Latched Mode Cycle Time tUL — 7 — ms From PWR_EN edge transition from inactive to active to begin error recovery Auto-Recovery Mode Cycle Time tCYCLE — 25 — ms Time delay before error condition check, programmable (UCS1003-1 only) 10-25 ms, default listed Auto-Recovery Delay tRST — 20 — ms Portable device attached, VBUS must be VTEST after this time, programmable (UCS1003-1 only) 10-25 ms, default listed Discharge Time tDISCHARGE — 200 — ms Amount of time discharge resistor applied, programmable (UCS1003-1 only) 100-400 ms, default listed Port Power Switch Operation with Trip Mode Current Limiting Region 2 Current Keep-out IBUS_R2MIN —0.12 — A Minimum VBUS Allowed at Output VBUS_MIN 1.5 2.0 2.25 V Port Power Switch Operation with Constant-Current Limiting (Variable Slope) Region 2 Current Keep-out IBUS_R2MIN —1.68 — A Minimum VBUS Allowed at Output VBUS_MIN 1.5 2.0 2.25 V Current Measurement (UCS1003-1 only) – DC Current Measurement Range IBUS_M 0 — 2988.6 mA Range 0-255 LSB (Note 4) Reported Current Measurement Resolution DIBUS_M — 11.72 — mA 1 LSB Current Measurement Accuracy —±2 — % 180 mA < IBUS < ILIM —±2 — LSB IBUS < 180 mA Current Measurement (UCS1003-1 only) – AC Sampling Rate — 500 — µs TABLE 1-2: ELECTRICAL CHARACTERISTICS (CONTINUED) Electrical Characteristics: Unless otherwise specified, VDD = 4.5V to 5.5V, VS = 2.9V to 5.5V, VPULLUP = 3V to 5.5V, TA = -40°C to +85°C; all Typical values at VDD = VS = 5V, TA = +27°C. Characteristic Sym. Min. Typ. Max. Unit Conditions Note 1: For split supply systems using the Attach Detection feature, VS must not exceed VDD +150 mV. 2: This parameter is ensured by design and not 100% tested. 3: This parameter is characterized, but not 100% production tested. 4: The current measurement full-scale range maximum value is 3.0A. However, the UCS1003-1 cannot report values above ILIM (if IBUS_R2MIN ILIM) or above IBUS_R2MIN (if IBUS_R2MIN > ILIM and ILIM 1.68A). 5: The Min and Max values represent the boundaries of a programmable range for UCS1003-1 only. Each value in the range is typical. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |